<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.0 20040830//EN" "http://dtd.nlm.nih.gov/publishing/2.0/journalpublishing.dtd">
<article article-type="review-article" dtd-version="2.0" xmlns:xlink="http://www.w3.org/1999/xlink">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">JA</journal-id>
      <journal-id journal-id-type="nlm-ta">JMIR Aging</journal-id>
      <journal-title>JMIR Aging</journal-title>
      <issn pub-type="epub">2561-7605</issn>
      <publisher>
        <publisher-name>JMIR Publications</publisher-name>
        <publisher-loc>Toronto, Canada</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">v7i1e52582</article-id>
      <article-id pub-id-type="pmid"/>
      <article-id pub-id-type="doi">10.2196/52582</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Review</subject>
        </subj-group>
        <subj-group subj-group-type="article-type">
          <subject>Review</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Markerless Motion Capture to Quantify Functional Performance in Neurodegeneration: Systematic Review</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="editor">
          <name>
            <surname>Wang</surname>
            <given-names>Jinjiao</given-names>
          </name>
        </contrib>
      </contrib-group>
      <contrib-group>
        <contrib contrib-type="reviewer">
          <name>
            <surname>Hill</surname>
            <given-names>Stephen</given-names>
          </name>
        </contrib>
        <contrib contrib-type="reviewer">
          <name>
            <surname>Ikefuama</surname>
            <given-names>Ebenezer</given-names>
          </name>
        </contrib>
      </contrib-group>
      <contrib-group>
        <contrib id="contrib1" contrib-type="author">
          <name name-style="western">
            <surname>Jeyasingh-Jacob</surname>
            <given-names>Julian</given-names>
          </name>
          <degrees>BOccThy, MSc</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <xref rid="aff2" ref-type="aff">2</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0001-7135-8470</ext-link>
        </contrib>
        <contrib id="contrib2" contrib-type="author">
          <name name-style="western">
            <surname>Crook-Rumsey</surname>
            <given-names>Mark</given-names>
          </name>
          <degrees>MSc, PhD</degrees>
          <xref rid="aff2" ref-type="aff">2</xref>
          <xref rid="aff3" ref-type="aff">3</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0003-3031-3502</ext-link>
        </contrib>
        <contrib id="contrib3" contrib-type="author">
          <name name-style="western">
            <surname>Shah</surname>
            <given-names>Harshvi</given-names>
          </name>
          <degrees>BSc, MS</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <xref rid="aff2" ref-type="aff">2</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0009-0001-1793-3160</ext-link>
        </contrib>
        <contrib id="contrib4" contrib-type="author">
          <name name-style="western">
            <surname>Joseph</surname>
            <given-names>Theresita</given-names>
          </name>
          <degrees>MSc, MBBS</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <xref rid="aff2" ref-type="aff">2</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0009-0005-9110-0182</ext-link>
        </contrib>
        <contrib id="contrib5" contrib-type="author">
          <name name-style="western">
            <surname>Abulikemu</surname>
            <given-names>Subati</given-names>
          </name>
          <degrees>MSc</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <xref rid="aff2" ref-type="aff">2</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0009-0008-4970-2173</ext-link>
        </contrib>
        <contrib id="contrib6" contrib-type="author">
          <name name-style="western">
            <surname>Daniels</surname>
            <given-names>Sarah</given-names>
          </name>
          <degrees>BASc, MSc</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <xref rid="aff2" ref-type="aff">2</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0002-7415-1907</ext-link>
        </contrib>
        <contrib id="contrib7" contrib-type="author">
          <name name-style="western">
            <surname>Sharp</surname>
            <given-names>David J</given-names>
          </name>
          <degrees>BA, MBBS, PhD</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <xref rid="aff2" ref-type="aff">2</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0003-4995-2240</ext-link>
        </contrib>
        <contrib id="contrib8" contrib-type="author" corresp="yes">
          <name name-style="western">
            <surname>Haar</surname>
            <given-names>Shlomi</given-names>
          </name>
          <degrees>MSc, PhD</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <address>
            <institution>Department of Brain Sciences</institution>
            <institution>Imperial College London</institution>
            <addr-line>Sir Michael Uren Research Hub</addr-line>
            <addr-line>London, W12 0BZ</addr-line>
            <country>United Kingdom</country>
            <phone>44 20 759 48064</phone>
            <email>s.haar@imperial.ac.uk</email>
          </address>
          <xref rid="aff2" ref-type="aff">2</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0003-2213-6585</ext-link>
        </contrib>
      </contrib-group>
      <aff id="aff1">
        <label>1</label>
        <institution>Department of Brain Sciences</institution>
        <institution>Imperial College London</institution>
        <addr-line>London</addr-line>
        <country>United Kingdom</country>
      </aff>
      <aff id="aff2">
        <label>2</label>
        <institution>Care Research and Technology Centre</institution>
        <institution>UK Dementia Research Institute</institution>
        <institution>Imperial College London</institution>
        <addr-line>London</addr-line>
        <country>United Kingdom</country>
      </aff>
      <aff id="aff3">
        <label>3</label>
        <institution>Department of Basic and Clinical Neuroscience</institution>
        <institution>King's College London</institution>
        <addr-line>London</addr-line>
        <country>United Kingdom</country>
      </aff>
      <author-notes>
        <corresp>Corresponding Author: Shlomi Haar <email>s.haar@imperial.ac.uk</email></corresp>
      </author-notes>
      <pub-date pub-type="collection">
        <year>2024</year>
      </pub-date>
      <pub-date pub-type="epub">
        <day>6</day>
        <month>8</month>
        <year>2024</year>
      </pub-date>
      <volume>7</volume>
      <elocation-id>e52582</elocation-id>
      <history>
        <date date-type="received">
          <day>8</day>
          <month>9</month>
          <year>2023</year>
        </date>
        <date date-type="rev-request">
          <day>7</day>
          <month>2</month>
          <year>2024</year>
        </date>
        <date date-type="rev-recd">
          <day>22</day>
          <month>3</month>
          <year>2024</year>
        </date>
        <date date-type="accepted">
          <day>15</day>
          <month>7</month>
          <year>2024</year>
        </date>
      </history>
      <copyright-statement>©Julian Jeyasingh-Jacob, Mark Crook-Rumsey, Harshvi Shah, Theresita Joseph, Subati Abulikemu, Sarah Daniels, David J Sharp, Shlomi Haar. Originally published in JMIR Aging (https://aging.jmir.org), 06.08.2024.</copyright-statement>
      <copyright-year>2024</copyright-year>
      <license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/">
        <p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Aging, is properly cited. The complete bibliographic information, a link to the original publication on https://aging.jmir.org, as well as this copyright and license information must be included.</p>
      </license>
      <self-uri xlink:href="https://aging.jmir.org/2024/1/e52582" xlink:type="simple"/>
      <abstract>
        <sec sec-type="background">
          <title>Background</title>
          <p>Markerless motion capture (MMC) uses video cameras or depth sensors for full body tracking and presents a promising approach for objectively and unobtrusively monitoring functional performance within community settings, to aid clinical decision-making in neurodegenerative diseases such as dementia.</p>
        </sec>
        <sec sec-type="objective">
          <title>Objective</title>
          <p>The primary objective of this systematic review was to investigate the application of MMC using full-body tracking, to quantify functional performance in people with dementia, mild cognitive impairment, and Parkinson disease.</p>
        </sec>
        <sec sec-type="methods">
          <title>Methods</title>
          <p>A systematic search of the Embase, MEDLINE, CINAHL, and Scopus databases was conducted between November 2022 and February 2023, which yielded a total of 1595 results. The inclusion criteria were MMC and full-body tracking. A total of 157 studies were included for full-text screening, out of which 26 eligible studies that met the selection criteria were included in the review. </p>
        </sec>
        <sec sec-type="results">
          <title>Results</title>
          <p>Primarily, the selected studies focused on gait analysis (n=24), while other functional tasks, such as sit to stand (n=5) and stepping in place (n=1), were also explored. However, activities of daily living were not evaluated in any of the included studies. MMC models varied across the studies, encompassing depth cameras (n=18) versus standard video cameras (n=5) or mobile phone cameras (n=2) with postprocessing using deep learning models. However, only 6 studies conducted rigorous comparisons with established gold-standard motion capture models.</p>
        </sec>
        <sec sec-type="conclusions">
          <title>Conclusions</title>
          <p>Despite its potential as an effective tool for analyzing movement and posture in individuals with dementia, mild cognitive impairment, and Parkinson disease, further research is required to establish the clinical usefulness of MMC in quantifying mobility and functional performance in the real world.</p>
        </sec>
      </abstract>
      <kwd-group>
        <kwd>markerless motion capture</kwd>
        <kwd>motion analysis</kwd>
        <kwd>movement analysis</kwd>
        <kwd>motion</kwd>
        <kwd>neurodegeneration</kwd>
        <kwd>neurodegenerative</kwd>
        <kwd>systematic review</kwd>
        <kwd>movement</kwd>
        <kwd>body tracking</kwd>
        <kwd>tracking</kwd>
        <kwd>monitoring</kwd>
        <kwd>clinical decision making</kwd>
        <kwd>decision</kwd>
        <kwd>decision making</kwd>
        <kwd>dementia</kwd>
        <kwd>neurodegenerative disease</kwd>
        <kwd>mild cognitive impairment</kwd>
        <kwd>Parkinson's disease</kwd>
        <kwd>tool</kwd>
        <kwd>mobility</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <body>
    <sec sec-type="introduction">
      <title>Introduction</title>
      <p>Markerless motion capture (MMC) technology uses sensors and advanced software algorithms to track and analyze human movement, without the attachment of physical markers to individuals or the use of external devices such as pressure sensors or wearables. There is growing use of MMC to provide highly accurate quantitative parameters of physical function including mobility [<xref ref-type="bibr" rid="ref1">1</xref>,<xref ref-type="bibr" rid="ref2">2</xref>], balance [<xref ref-type="bibr" rid="ref3">3</xref>], upper extremity tasks [<xref ref-type="bibr" rid="ref4">4</xref>], and activities of daily living (ADL) [<xref ref-type="bibr" rid="ref5">5</xref>].</p>
      <p>While 3D motion capture systems using markers are considered the gold standard for movement analysis, they have several limitations including their lack of portability, the need for trained staff, and the requirement for reflective markers to be placed precisely on participants’ bodies [<xref ref-type="bibr" rid="ref6">6</xref>]. In contrast, the use of MMC provides several advantages: being easier to operate, requiring less space, and being more economical than traditional marker-based systems [<xref ref-type="bibr" rid="ref7">7</xref>]. Importantly, their ability to capture movement unobtrusively is a key benefit for user compliance [<xref ref-type="bibr" rid="ref8">8</xref>], particularly when working with individuals with cognitive impairments.</p>
      <p>MMC is attractive for health care and research use, such as monitoring functional performance loss or improvement in neurodegenerative diseases. While traditional movement analyses are based on subjective clinical assessments, MMC can be used to generate objective and quantifiable digital biomarkers that can help detect a decline in functional performance by capturing movement unobtrusively [<xref ref-type="bibr" rid="ref9">9</xref>]. Variations in these digital biomarkers could indicate underlying impairment and enable earlier support. The fact that MMC can be deployed in home environments may avoid unnecessary hospital visits for patients, as well as detect subtle changes in functional ability that may only be apparent in everyday home-based settings rather than within a clinic.</p>
      <p>Several MMC devices can provide cost-effective assessments of functional performance in research and clinical settings. Broadly, the 2 main types of MMC camera hardware are depth cameras and standard red-green-blue (RGB) video cameras, used in single or multicamera systems. Commonly used and widely accessible depth cameras are the Kinect (Microsoft) devices, which use standard RGB color video as well as depth estimation by recording the distance between the camera and each pixel through the emission of structured light patterns [<xref ref-type="bibr" rid="ref10">10</xref>]. Machine learning algorithms can be used to reconstruct 3D skeletal models in real-time from the RBG+depth (RBG-D) image. Alternatively, deep learning can be used with standard video cameras or mobile phone cameras to record limb location and orientation. This method uses deep neural networks trained from large datasets to estimate body segment position and orientation (pose) and motion tracking, without explicit depth sensing. It requires specific body segment positions known as the 6 degrees of freedom: 3 rotational (flexion or extension, abduction or adduction, and rotation about the longitudinal axis) and 3 translational (sagittal, frontal, and transverse) [<xref ref-type="bibr" rid="ref11">11</xref>]. Both forms of MMC have shown promising use thus far.</p>
      <p>A scoping review of single-camera MMC models used in health care highlighted the significant potential for use in clinical applications but also noted the need to improve their tracking accuracy [<xref ref-type="bibr" rid="ref12">12</xref>]. A previous systematic review of MMC-based training devices used in neurological rehabilitation found that these devices improve motivation and enable better functional performance potentially due to the gaming element [<xref ref-type="bibr" rid="ref13">13</xref>]. Another systematic review of MMC-based devices in rehabilitation found that balance training with the support of MMC resulted in better outcomes potentially due to more dynamic training conditions [<xref ref-type="bibr" rid="ref14">14</xref>]. While those systematic reviews explored the use of MMC specifically in rehabilitation training, this review focuses on the technology-based evaluation of functional tasks. The recent increase in the number of studies involving MMC-based movement analysis in neurodegenerative diseases offers a strong rationale for this review. This trend includes the use of MMC to track gait decline [<xref ref-type="bibr" rid="ref9">9</xref>], assess fall risks [<xref ref-type="bibr" rid="ref15">15</xref>,<xref ref-type="bibr" rid="ref16">16</xref>], detect disease traits [<xref ref-type="bibr" rid="ref17">17</xref>], estimate disease severity [<xref ref-type="bibr" rid="ref18">18</xref>], and detect cognitive impairment from gait features [<xref ref-type="bibr" rid="ref19">19</xref>].</p>
      <p>Neurodegenerative diseases such as dementia and Parkinson disease (PD) lead to declining functional performance. Detecting problems in everyday functional tasks in these patient groups can help provide early, timely, and clinically appropriate interventions that may help maintain independence, decrease caregiver burden, and potentially slow the rate of functional decline [<xref ref-type="bibr" rid="ref20">20</xref>,<xref ref-type="bibr" rid="ref21">21</xref>]. MMC can provide digitally measured functional performance data that could be used to enhance clinical decision-making and remote monitoring; identify risks such as falls; and better capture the impact of rehabilitative, pharmacological, and surgical interventions. Although MMC technology could offer the potential for detecting functional changes in neurodegenerative diseases, a model that is comparable to established gold-standard motion capture systems is essential for deployment in real-world applications. This study aimed to complete a systematic review of published literature on the use of MMC with full-body tracking for quantifying functional performance in people with dementia, mild cognitive impairment (MCI), and PD.</p>
    </sec>
    <sec sec-type="methods">
      <title>Methods</title>
      <sec>
        <title>Study Design</title>
        <p>The web-based Covidence (Veritas Health Innovation) software platform was used in this review, and the titles and abstracts were screened by 2 independent reviewers. The full text of the relevant studies was reviewed, and the quality of the studies was assessed by 2 independent reviewers. Data extraction was also performed by 2 independent reviewers, and any conflicts were resolved through discussion.</p>
      </sec>
      <sec>
        <title>Search Strategy</title>
        <p>The search strategy was designed to include all types of studies that used MMC with full-body tracking in individuals with dementia, MCI, or PD. To identify relevant studies, a combination of both the Medical Subject Headings thesaurus and free-text terms related to the 3 conditions and MMC technology were used. The search included publications from all years in the CINAHL, Embase, MEDLINE, and Scopus databases using the terms “Motion Capture,” “Motion Analysis,” “Movement Analysis,” and “Pose Estimation” in combination with “Dementia,” “Mild cognitive impairment,” and “Parkinson’s disease.” The details of the search activity can be found in <xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>.</p>
      </sec>
      <sec>
        <title>Inclusion and Exclusion Criteria</title>
        <p>The inclusion criteria for the systematic review were as follows: (1) markerless optical motion capture; (2) full-body tracking; (3) involving participants with dementia, MCI, or PD; (4) original research; and (5) English language studies. Studies with the following characteristics were excluded: (1) motion capture with markers, inertial measurement units, body-worn sensors, or pressure sensors; (2) movement analysis of specific parts of the body or symptoms such as tremor and rigidity; (3) evaluating interventions such as exercises, deep brain stimulation, medication, rehabilitation protocol, dance, and gaming; and (4) pose estimation of videos found on the internet.</p>
      </sec>
      <sec>
        <title>Data Extraction</title>
        <p>The general information extracted from the studies included: the center and country where the study took place; study characteristics; funding sources; age, sex, and number of participants; number and duration of visits; study aims; inclusion and exclusion criteria; and the main disease condition evaluated. Methodological information extracted included technical details of the MMC system used; functional performance area evaluated, for example, gait or sit to stand; software used for feature extraction; and the method of analysis. The results information extracted included the following: statistically significant movement features, whether they were measured under single or dual task (motor or cognitive) conditions, whether compared to established gold standard models or a relevant clinical measure, and key outcomes including the level of accuracy obtained.</p>
      </sec>
    </sec>
    <sec sec-type="results">
      <title>Results</title>
      <sec>
        <title>Study Selection</title>
        <p>The literature search yielded 1595 results; after removing duplicates, 1159 studies remained for title or abstract screening. Subsequently, 131 studies were identified for full-text screening, of which 26 studies met the inclusion criteria and were included in the review. A PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) flowchart [<xref ref-type="bibr" rid="ref22">22</xref>] outlining the selection process can be found in <xref rid="figure1" ref-type="fig">Figure 1</xref>.</p>
        <fig id="figure1" position="float">
          <label>Figure 1</label>
          <caption>
            <p>PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) 2020 flow diagram for new systematic reviews.</p>
          </caption>
          <graphic xlink:href="aging_v7i1e52582_fig1.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>
      </sec>
      <sec>
        <title>Quality Assessment</title>
        <p>The 26 selected studies were assessed for quality using the Specialist Unit for Review Evidence questions to assist with the critical appraisal of the cross-sectional studies tool [<xref ref-type="bibr" rid="ref23">23</xref>]. While no studies were excluded from the review based on this assessment, issues pertaining to quality were identified within several of the studies. <xref ref-type="table" rid="table1">Table 1</xref> shows that all studies included in this review used appropriate outcome measures (n=26, 100%). Most studies clearly stated the study design (n=20, 77%); provided information on the study setting, location, and dates (n=20, 77%); described the results well (n=19, 73%); and provided participant characteristics (n=16, 62%). However, few studies reported if participants were fairly selected (n=10, 38%) or provided information on participant eligibility (n=2, 8%) and handling of missing data and control of potential biases (n=1, 4%).</p>
        <table-wrap position="float" id="table1">
          <label>Table 1</label>
          <caption>
            <p>Quality assessment summary.</p>
          </caption>
          <table width="1000" cellpadding="5" cellspacing="0" border="1" rules="groups" frame="hsides">
            <col width="110"/>
            <col width="80"/>
            <col width="100"/>
            <col width="100"/>
            <col width="100"/>
            <col width="110"/>
            <col width="100"/>
            <col width="110"/>
            <col width="100"/>
            <col width="90"/>
            <thead>
              <tr valign="top">
                <td>Study</td>
                <td>Is the study design clearly stated?</td>
                <td>Are the setting, location, and relevant dates provided?</td>
                <td>Were participants fairly selected?</td>
                <td>Are participant characteristics provided?</td>
                <td>Are the measures of exposures and outcomes appropriate?</td>
                <td>Is there a description of how the study size was arrived at?</td>
                <td>Is there information on how missing data was handled and whether sources of bias were controlled for?</td>
                <td>Is information provided on participant eligibility?</td>
                <td>Are the results well described?</td>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td>Cimolin et al (2022) [<xref ref-type="bibr" rid="ref24">24</xref>]</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
              </tr>
              <tr valign="top">
                <td>Kaur et al (2023) [<xref ref-type="bibr" rid="ref25">25</xref>]</td>
                <td>✓</td>
                <td>✓</td>
                <td>Not reported</td>
                <td>✓</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>✓</td>
              </tr>
              <tr valign="top">
                <td>Khan et al (2021) [<xref ref-type="bibr" rid="ref26">26</xref>]</td>
                <td>✓</td>
                <td>✓</td>
                <td>Not reported</td>
                <td>✓</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
              </tr>
              <tr valign="top">
                <td>Khan et al (2013) [<xref ref-type="bibr" rid="ref27">27</xref>]</td>
                <td>X</td>
                <td>✓</td>
                <td>Not reported</td>
                <td>X</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
              </tr>
              <tr valign="top">
                <td>Kondragunta et al (2020) [<xref ref-type="bibr" rid="ref19">19</xref>]</td>
                <td>X</td>
                <td>✓</td>
                <td>Not reported</td>
                <td>X</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
              </tr>
              <tr valign="top">
                <td>Lai et al (2022) [<xref ref-type="bibr" rid="ref28">28</xref>]</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>✓</td>
              </tr>
              <tr valign="top">
                <td>Li et al (2018) [<xref ref-type="bibr" rid="ref29">29</xref>]</td>
                <td>X</td>
                <td>✓</td>
                <td>Not reported</td>
                <td>X</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>✓</td>
              </tr>
              <tr valign="top">
                <td>Mehdizadeh et al (2021) [<xref ref-type="bibr" rid="ref9">9</xref>]</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>✓</td>
                <td>✓</td>
              </tr>
              <tr valign="top">
                <td>Mehdizadeh et al (2021) [<xref ref-type="bibr" rid="ref15">15</xref>]</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>X</td>
                <td>✓</td>
                <td>✓</td>
              </tr>
              <tr valign="top">
                <td>Morinan et al (2022) [<xref ref-type="bibr" rid="ref30">30</xref>]</td>
                <td>✓</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
              </tr>
              <tr valign="top">
                <td>Muñoz-Ospina et al (2022) [<xref ref-type="bibr" rid="ref31">31</xref>]</td>
                <td>✓</td>
                <td>✓</td>
                <td>Not reported</td>
                <td>✓</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>✓</td>
              </tr>
              <tr valign="top">
                <td>Ng et al (2020) [<xref ref-type="bibr" rid="ref16">16</xref>]</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>✓</td>
              </tr>
              <tr valign="top">
                <td>Ospina et al (2021) [<xref ref-type="bibr" rid="ref32">32</xref>]</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>✓</td>
              </tr>
              <tr valign="top">
                <td>Otte et al (2020) [<xref ref-type="bibr" rid="ref33">33</xref>]</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>X</td>
                <td>✓</td>
              </tr>
              <tr valign="top">
                <td>Pedro et al (2020) [<xref ref-type="bibr" rid="ref34">34</xref>]</td>
                <td>X</td>
                <td>X</td>
                <td>Not reported</td>
                <td>✓</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
              </tr>
              <tr valign="top">
                <td>Procházka et al (2015) [<xref ref-type="bibr" rid="ref35">35</xref>]</td>
                <td>X</td>
                <td>X</td>
                <td>Not reported</td>
                <td>X</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>✓</td>
              </tr>
              <tr valign="top">
                <td>Rupprechter et al (2021) [<xref ref-type="bibr" rid="ref36">36</xref>]</td>
                <td>✓</td>
                <td>X</td>
                <td>Not reported</td>
                <td>X</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>✓</td>
              </tr>
              <tr valign="top">
                <td>Sabo et al (2022) [<xref ref-type="bibr" rid="ref18">18</xref>]</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>✓</td>
              </tr>
              <tr valign="top">
                <td>Sabo et al (2022) [<xref ref-type="bibr" rid="ref37">37</xref>]</td>
                <td>✓</td>
                <td>✓</td>
                <td>Not reported</td>
                <td>✓</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>✓</td>
              </tr>
              <tr valign="top">
                <td>Sabo et al (2021) [<xref ref-type="bibr" rid="ref17">17</xref>]</td>
                <td>✓</td>
                <td>✓</td>
                <td>Not reported</td>
                <td>X</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
              </tr>
              <tr valign="top">
                <td>Sabo et al (2020) [<xref ref-type="bibr" rid="ref38">38</xref>]</td>
                <td>✓</td>
                <td>X</td>
                <td>Not reported</td>
                <td>✓</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>✓</td>
              </tr>
              <tr valign="top">
                <td>Seifallahi et al (2022) [<xref ref-type="bibr" rid="ref39">39</xref>]</td>
                <td>✓</td>
                <td>X</td>
                <td>Not reported</td>
                <td>X</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>✓</td>
              </tr>
              <tr valign="top">
                <td>Shin et al (2021) [<xref ref-type="bibr" rid="ref40">40</xref>]</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>✓</td>
              </tr>
              <tr valign="top">
                <td>Soltaninejad et al (2018) [<xref ref-type="bibr" rid="ref41">41</xref>]</td>
                <td>X</td>
                <td>✓</td>
                <td>Not reported</td>
                <td>X</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>✓</td>
              </tr>
              <tr valign="top">
                <td>Tan et al (2019) [<xref ref-type="bibr" rid="ref42">42</xref>]</td>
                <td>✓</td>
                <td>X</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>✓</td>
              </tr>
              <tr valign="top">
                <td>Ťupa et al (2015) [<xref ref-type="bibr" rid="ref43">43</xref>]</td>
                <td>✓</td>
                <td>✓</td>
                <td>Not reported</td>
                <td>X</td>
                <td>✓</td>
                <td>X</td>
                <td>X</td>
                <td>X</td>
                <td>✓</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
      </sec>
      <sec>
        <title>Patient Groups</title>
        <p>The 26 studies comprised 18 involving participants with PD, 6 involving participants with dementia, and 2 involving participants with MCI. Most (18/26, 69%) of the studies used Kinect sensors for MMC. All studies that included participants with dementia (n=6) used the Kinect sensor and were conducted in inpatient settings. The Kinect was used to quantify gait decline over 10 weeks [<xref ref-type="bibr" rid="ref9">9</xref>], propose a prognostic model for fall risk [<xref ref-type="bibr" rid="ref15">15</xref>], and demonstrate the association with clinical gait measures and future falls [<xref ref-type="bibr" rid="ref16">16</xref>]. In inpatients with dementia and drug-induced Parkinsonism, the Kinect was used to capture Parkinsonian traits [<xref ref-type="bibr" rid="ref17">17</xref>]; quantify Parkinsonian gait [<xref ref-type="bibr" rid="ref38">38</xref>]; and along with pose estimation of recordings from a video camera, estimate Parkinsonian severity [<xref ref-type="bibr" rid="ref18">18</xref>]. It was also used in the MCI studies reviewed (n=2), as a tool to detect MCI from gait features [<xref ref-type="bibr" rid="ref19">19</xref>,<xref ref-type="bibr" rid="ref39">39</xref>].</p>
        <p>Of the 18 studies that included participants with PD, 10 (56%) reported the use of the Kinect sensor for analyzing gait, including its feasibility to extract relevant features [<xref ref-type="bibr" rid="ref34">34</xref>,<xref ref-type="bibr" rid="ref42">42</xref>], ability to detect PD [<xref ref-type="bibr" rid="ref24">24</xref>,<xref ref-type="bibr" rid="ref32">32</xref>,<xref ref-type="bibr" rid="ref41">41</xref>,<xref ref-type="bibr" rid="ref43">43</xref>], and ability to measure clinical disease severity [<xref ref-type="bibr" rid="ref28">28</xref>,<xref ref-type="bibr" rid="ref31">31</xref>,<xref ref-type="bibr" rid="ref33">33</xref>]. Alternative MMC models that use image processing for pose estimation of videos from RGB cameras have also been used with participants with PD, demonstrating the feasibility of these models in quantifying gait impairment and disease severity [<xref ref-type="bibr" rid="ref18">18</xref>,<xref ref-type="bibr" rid="ref25">25</xref>-<xref ref-type="bibr" rid="ref27">27</xref>,<xref ref-type="bibr" rid="ref29">29</xref>,<xref ref-type="bibr" rid="ref30">30</xref>,<xref ref-type="bibr" rid="ref36">36</xref>,<xref ref-type="bibr" rid="ref40">40</xref>].</p>
      </sec>
      <sec>
        <title>Functional Performance Components</title>
        <p>Most studies (24/26, 92%) evaluated aspects of gait, although there were significant variations in the features extracted and methods used for analysis, with some of them lacking statistical significance. Other functional performance components evaluated were sit to stand (n=5) and stepping in place (n=1). <xref ref-type="table" rid="table2">Table 2</xref> shows functional performance components by study.</p>
        <table-wrap position="float" id="table2">
          <label>Table 2</label>
          <caption>
            <p>Patient groups, functional performance components, and feature extraction categories.</p>
          </caption>
          <table width="1000" cellpadding="5" cellspacing="0" border="1" rules="groups" frame="hsides">
            <col width="310"/>
            <col width="150"/>
            <col width="270"/>
            <col width="270"/>
            <thead>
              <tr valign="top">
                <td>Study</td>
                <td>Patient group</td>
                <td>Functional performance component</td>
                <td>Feature category</td>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td>Cimolin et al (2022) [<xref ref-type="bibr" rid="ref24">24</xref>]</td>
                <td>PD<sup>a</sup></td>
                <td>Gait</td>
                <td>Spatiotemporal and stability</td>
              </tr>
              <tr valign="top">
                <td>Kaur et al (2023) [<xref ref-type="bibr" rid="ref25">25</xref>]</td>
                <td>PD</td>
                <td>Gait</td>
                <td>Spatiotemporal and symmetry</td>
              </tr>
              <tr valign="top">
                <td>Khan et al (2021) [<xref ref-type="bibr" rid="ref26">26</xref>]</td>
                <td>PD</td>
                <td>Gait</td>
                <td>Spatiotemporal</td>
              </tr>
              <tr valign="top">
                <td>Khan et al (2013) [<xref ref-type="bibr" rid="ref27">27</xref>]</td>
                <td>PD</td>
                <td>Gait</td>
                <td>Gait posture and spatiotemporal</td>
              </tr>
              <tr valign="top">
                <td>Kondragunta et al (2020) [<xref ref-type="bibr" rid="ref19">19</xref>]</td>
                <td>MCI<sup>b</sup></td>
                <td>Gait</td>
                <td>Spatiotemporal</td>
              </tr>
              <tr valign="top">
                <td>Lai et al (2022) [<xref ref-type="bibr" rid="ref28">28</xref>]</td>
                <td>PD</td>
                <td>Gait</td>
                <td>Spatiotemporal and ROM<sup>c</sup></td>
              </tr>
              <tr valign="top">
                <td>Li et al (2018) [<xref ref-type="bibr" rid="ref29">29</xref>]</td>
                <td>PD</td>
                <td>Sit to stand and gait</td>
                <td>Spatiotemporal</td>
              </tr>
              <tr valign="top">
                <td>Mehdizadeh et al (2021) [<xref ref-type="bibr" rid="ref9">9</xref>]</td>
                <td>Dementia</td>
                <td>Gait</td>
                <td>Spatiotemporal, ROM, and stability</td>
              </tr>
              <tr valign="top">
                <td>Mehdizadeh et al (2021) [<xref ref-type="bibr" rid="ref15">15</xref>]</td>
                <td>Dementia</td>
                <td>Gait</td>
                <td>Spatiotemporal, stability, and symmetry</td>
              </tr>
              <tr valign="top">
                <td>Morinan et al (2022) [<xref ref-type="bibr" rid="ref30">30</xref>]</td>
                <td>PD</td>
                <td>Sit to stand</td>
                <td>Spatiotemporal</td>
              </tr>
              <tr valign="top">
                <td>Muñoz-Ospina et al (2022) [<xref ref-type="bibr" rid="ref31">31</xref>]</td>
                <td>PD</td>
                <td>Gait</td>
                <td>Spatiotemporal and symmetry</td>
              </tr>
              <tr valign="top">
                <td>Ng et al (2020) [<xref ref-type="bibr" rid="ref16">16</xref>]</td>
                <td>Dementia</td>
                <td>Gait</td>
                <td>Stability</td>
              </tr>
              <tr valign="top">
                <td>Ospina et al (2021) [<xref ref-type="bibr" rid="ref32">32</xref>]</td>
                <td>PD</td>
                <td>Gait</td>
                <td>Spatiotemporal and symmetry</td>
              </tr>
              <tr valign="top">
                <td>Otte et al (2020) [<xref ref-type="bibr" rid="ref33">33</xref>]</td>
                <td>PD</td>
                <td>Stepping in place</td>
                <td>Spatiotemporal, symmetry, and rhythmicity</td>
              </tr>
              <tr valign="top">
                <td>Pedro et al (2020) [<xref ref-type="bibr" rid="ref34">34</xref>]</td>
                <td>PD</td>
                <td>Gait</td>
                <td>Spatiotemporal</td>
              </tr>
              <tr valign="top">
                <td>Procházka et al (2015) [<xref ref-type="bibr" rid="ref35">35</xref>]</td>
                <td>PD</td>
                <td>Gait</td>
                <td>Spatiotemporal</td>
              </tr>
              <tr valign="top">
                <td>Rupprechter et al (2021) [<xref ref-type="bibr" rid="ref36">36</xref>]</td>
                <td>PD</td>
                <td>Gait</td>
                <td>Spatiotemporal</td>
              </tr>
              <tr valign="top">
                <td>Sabo et al (2022) [<xref ref-type="bibr" rid="ref37">37</xref>]</td>
                <td>PD</td>
                <td>Gait</td>
                <td>Spatiotemporal</td>
              </tr>
              <tr valign="top">
                <td>Sabo et al (2022) [<xref ref-type="bibr" rid="ref18">18</xref>]</td>
                <td>Dementia</td>
                <td>Gait</td>
                <td>Spatiotemporal, stability, and symmetry</td>
              </tr>
              <tr valign="top">
                <td>Sabo et al (2021) [<xref ref-type="bibr" rid="ref17">17</xref>]</td>
                <td>Dementia</td>
                <td>Gait</td>
                <td>Spatiotemporal, stability, and symmetry</td>
              </tr>
              <tr valign="top">
                <td>Sabo et al (2020) [<xref ref-type="bibr" rid="ref38">38</xref>]</td>
                <td>Dementia</td>
                <td>Gait</td>
                <td>Spatiotemporal, stability, and symmetry</td>
              </tr>
              <tr valign="top">
                <td>Seifallahi et al (2022) [<xref ref-type="bibr" rid="ref39">39</xref>]</td>
                <td>MCI</td>
                <td>Gait</td>
                <td>Spatiotemporal</td>
              </tr>
              <tr valign="top">
                <td>Shin et al (2021) [<xref ref-type="bibr" rid="ref40">40</xref>]</td>
                <td>PD</td>
                <td>Gait and sit to stand</td>
                <td>Spatiotemporal</td>
              </tr>
              <tr valign="top">
                <td>Soltaninejad et al (2018) [<xref ref-type="bibr" rid="ref41">41</xref>]</td>
                <td>PD</td>
                <td>Gait and sit to stand</td>
                <td>Spatiotemporal</td>
              </tr>
              <tr valign="top">
                <td>Tan et al (2019) [<xref ref-type="bibr" rid="ref42">42</xref>]</td>
                <td>PD</td>
                <td>Gait and sit to stand</td>
                <td>Spatiotemporal and stability</td>
              </tr>
              <tr valign="top">
                <td>Ťupa et al (2015) [<xref ref-type="bibr" rid="ref43">43</xref>]</td>
                <td>PD</td>
                <td>Gait</td>
                <td>Spatiotemporal</td>
              </tr>
            </tbody>
          </table>
          <table-wrap-foot>
            <fn id="table2fn1">
              <p><sup>a</sup>PD: Parkinson disease.</p>
            </fn>
            <fn id="table2fn2">
              <p><sup>b</sup>MCI: mild cognitive impairment.</p>
            </fn>
            <fn id="table2fn3">
              <p><sup>c</sup>ROM: range of motion.</p>
            </fn>
          </table-wrap-foot>
        </table-wrap>
      </sec>
      <sec>
        <title>Feature Categories</title>
        <p><xref ref-type="table" rid="table2">Table 2</xref> shows extraction feature categories by study. Spatiotemporal features of gait that were reported as having statistical significance included spatial parameters, such as step length (n=8), step width (n=5), and stride length (n=4), and temporal parameters, such as cadence (n=5), gait velocity (n=4), step time (n=4), stance duration (n=1), double support duration (n=1), stride time (n=1), turning time (n=1), turning speed (n=1), swing time (n=1), step velocity (n=1), and stride velocity (n=1). Other extracted feature categories included symmetry (n=9), stability (n=8), range of motion (n=2), and rhythmicity (n=1).</p>
      </sec>
      <sec>
        <title>MMC Devices and Feature Extraction Methods</title>
        <p><xref ref-type="table" rid="table3">Table 3</xref> shows that most studies (18/26, 69%) used Kinect depth cameras (4 used V1; 12 used V2; 1 used Kinect eMotion; and the latest version, the Azure Kinect, was used in 1 study), while the remainder used regular video or mobile phone cameras. Common camera positioning included frontal views (n=4), ceiling-mounted (n=4), and multiple cameras from different angles (n=3). However, camera position was not reported in 7 of the study papers. The majority of studies have developed their own custom programs (n=10, 38%) or have used open-source libraries (n=8, 31%) to identify bodies in frame and extract movements. The use of propriety software was less common (n=5).</p>
        <table-wrap position="float" id="table3">
          <label>Table 3</label>
          <caption>
            <p>Markerless motion capture devices and feature extraction methods used.</p>
          </caption>
          <table width="1000" cellpadding="5" cellspacing="0" border="1" rules="groups" frame="hsides">
            <col width="190"/>
            <col width="160"/>
            <col width="130"/>
            <col width="140"/>
            <col width="180"/>
            <col width="200"/>
            <thead>
              <tr valign="top">
                <td>Study</td>
                <td>Device (camera or sensor)</td>
                <td>Devices, n</td>
                <td>Frames per second (fps or Hz)</td>
                <td>Position of cameras</td>
                <td>Extraction methods</td>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td>Cimolin et al (2022) [<xref ref-type="bibr" rid="ref24">24</xref>]</td>
                <td>Kinect V2</td>
                <td>1</td>
                <td>30</td>
                <td>Tripod in front</td>
                <td>Custom algorithm</td>
              </tr>
              <tr valign="top">
                <td>Kaur et al (2023) [<xref ref-type="bibr" rid="ref25">25</xref>]</td>
                <td>Video camera</td>
                <td>2</td>
                <td>30</td>
                <td>Front and right side</td>
                <td>OpenPose</td>
              </tr>
              <tr valign="top">
                <td>Khan et al (2021) [<xref ref-type="bibr" rid="ref26">26</xref>]</td>
                <td>Video camera</td>
                <td>1</td>
                <td>25</td>
                <td>Front</td>
                <td>Custom algorithm</td>
              </tr>
              <tr valign="top">
                <td>Khan et al (2013) [<xref ref-type="bibr" rid="ref27">27</xref>]</td>
                <td>Video camera</td>
                <td>1</td>
                <td>5</td>
                <td>Not reported</td>
                <td>Custom algorithm</td>
              </tr>
              <tr valign="top">
                <td>Kondragunta et al (2020) [<xref ref-type="bibr" rid="ref19">19</xref>]</td>
                <td>Kinect V2</td>
                <td>1</td>
                <td>20</td>
                <td>Not reported</td>
                <td>OpenPose</td>
              </tr>
              <tr valign="top">
                <td>Lai et al (2022) [<xref ref-type="bibr" rid="ref28">28</xref>]</td>
                <td>Kinect V2</td>
                <td>Not reported</td>
                <td>30</td>
                <td>Not reported</td>
                <td>GaitBEST (LongGood Meditech)</td>
              </tr>
              <tr valign="top">
                <td>Li et al (2018) [<xref ref-type="bibr" rid="ref29">29</xref>]</td>
                <td>Video camera</td>
                <td>1</td>
                <td>25</td>
                <td>Not reported</td>
                <td>Iterative Error Feedback and OpenPose</td>
              </tr>
              <tr valign="top">
                <td>Mehdizadeh et al (2021) [<xref ref-type="bibr" rid="ref9">9</xref>]</td>
                <td>Kinect V2</td>
                <td>1</td>
                <td>Not reported</td>
                <td>Ceiling in hallway</td>
                <td>Custom algorithm</td>
              </tr>
              <tr valign="top">
                <td>Mehdizadeh et al (2021) [<xref ref-type="bibr" rid="ref15">15</xref>]</td>
                <td>Kinect V2</td>
                <td>1</td>
                <td>Not reported</td>
                <td>Ceiling in hallway</td>
                <td>Custom algorithm</td>
              </tr>
              <tr valign="top">
                <td>Morinan et al (2022) [<xref ref-type="bibr" rid="ref30">30</xref>]</td>
                <td>Mobile phone camera and KELVIN-PD (Machine Medicine) mobile app</td>
                <td>Not reported</td>
                <td>Not reported</td>
                <td>Not reported</td>
                <td>OpenPose</td>
              </tr>
              <tr valign="top">
                <td>Munoz-Ospina et al (2022) [<xref ref-type="bibr" rid="ref31">31</xref>]</td>
                <td>Kinect eMotion</td>
                <td>1</td>
                <td>Not reported</td>
                <td>Not reported</td>
                <td>Custom algorithm</td>
              </tr>
              <tr valign="top">
                <td>Ng et al (2020) [<xref ref-type="bibr" rid="ref16">16</xref>]</td>
                <td>Kinect V2</td>
                <td>1</td>
                <td>30</td>
                <td>Ceiling at the end of a hallway</td>
                <td>OpenPose</td>
              </tr>
              <tr valign="top">
                <td>Ospina et al (2021) [<xref ref-type="bibr" rid="ref32">32</xref>]</td>
                <td>Kinect V1</td>
                <td>1</td>
                <td>Not reported</td>
                <td>Participants walking toward the camera</td>
                <td>Custom algorithm</td>
              </tr>
              <tr valign="top">
                <td>Otte et al (2020) [<xref ref-type="bibr" rid="ref33">33</xref>]</td>
                <td>Kinect V1</td>
                <td>1</td>
                <td>30</td>
                <td>1.4 m height in front</td>
                <td>Custom algorithm</td>
              </tr>
              <tr valign="top">
                <td>Pedro et al (2020) [<xref ref-type="bibr" rid="ref34">34</xref>]</td>
                <td>Azure Kinect</td>
                <td>3</td>
                <td>30</td>
                <td>Each end of walkway and halfway between</td>
                <td>Azure Kinect SDK to extract joint positions to estimate 32 body joint poses from depth color recordings</td>
              </tr>
              <tr valign="top">
                <td>Procházka et al (2015) [<xref ref-type="bibr" rid="ref35">35</xref>]</td>
                <td>Kinect V1</td>
                <td>1</td>
                <td>30</td>
                <td>60 cm above floor</td>
                <td>Custom algorithm</td>
              </tr>
              <tr valign="top">
                <td>Rupprechter et al (2021) [<xref ref-type="bibr" rid="ref36">36</xref>]</td>
                <td>Mobile phone camera and KELVIN-PD (Machine Medicine) mobile app</td>
                <td>1</td>
                <td>Not reported</td>
                <td>Patients walking directly toward or away from the camera in hallways or office settings</td>
                <td>OpenPose</td>
              </tr>
              <tr valign="top">
                <td>Sabo et al (2022) [<xref ref-type="bibr" rid="ref37">37</xref>]</td>
                <td>Logitech C920</td>
                <td>1</td>
                <td>30</td>
                <td>Tripod mounted, at one end of walkway</td>
                <td>AlphaPose (Shanghai Jiao Tong University), Detectron (Facebook AI Research), OpenPose, and ROMP (Regress All Meshes in a One-Stage Fashion for Multiple 3D People; JD AI research)</td>
              </tr>
              <tr valign="top">
                <td>Sabo et al (2022) [<xref ref-type="bibr" rid="ref18">18</xref>]</td>
                <td>Kinect V2 and mobile phone cameras</td>
                <td>1</td>
                <td>30</td>
                <td>Kinect: hallway ceiling; stationary mobile phone camera: participants walked toward and away from</td>
                <td>OpenPose, Detectron, and AlphaPose</td>
              </tr>
              <tr valign="top">
                <td>Sabo et al (2021) [<xref ref-type="bibr" rid="ref17">17</xref>]</td>
                <td>Kinect V2</td>
                <td>1</td>
                <td>30</td>
                <td>Ceiling in hallway</td>
                <td>AlphaPose and engineered 2D gait features from joint trajectories</td>
              </tr>
              <tr valign="top">
                <td>Sabo et al (2020) [<xref ref-type="bibr" rid="ref38">38</xref>]</td>
                <td>Kinect V2</td>
                <td>1</td>
                <td>30</td>
                <td>Ceiling in hallway</td>
                <td>OpenPose</td>
              </tr>
              <tr valign="top">
                <td>Seifallahi et al (2022) [<xref ref-type="bibr" rid="ref39">39</xref>]</td>
                <td>Kinect V2</td>
                <td>1</td>
                <td>Not reported</td>
                <td>On a tripod at a suitable distance from an oval path</td>
                <td>Custom algorithm</td>
              </tr>
              <tr valign="top">
                <td>Shin et al (2021) [<xref ref-type="bibr" rid="ref40">40</xref>]</td>
                <td>Video camera</td>
                <td>1</td>
                <td>30</td>
                <td>Frontal view from a tripod-mounted camera 1.5 m from the horizontal line of the turning point</td>
                <td>OpenPose, OpenCV</td>
              </tr>
              <tr valign="top">
                <td>Soltaninejad et al (2018) [<xref ref-type="bibr" rid="ref41">41</xref>]</td>
                <td>Kinect V2</td>
                <td>Not reported</td>
                <td>30</td>
                <td>Not reported</td>
                <td>Graph model of body skeleton</td>
              </tr>
              <tr valign="top">
                <td>Tan et al (2019) [<xref ref-type="bibr" rid="ref42">42</xref>]</td>
                <td>Kinect V2</td>
                <td>1</td>
                <td>Not reported</td>
                <td>End of walkway</td>
                <td>Custom algorithm</td>
              </tr>
              <tr valign="top">
                <td>Ťupa et al (2015) [<xref ref-type="bibr" rid="ref43">43</xref>]</td>
                <td>Kinect V1</td>
                <td>1</td>
                <td>30</td>
                <td>60 cm above floor</td>
                <td>Custom algorithm</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
      </sec>
      <sec>
        <title>Key Findings</title>
        <p><xref ref-type="table" rid="table4">Tables 4</xref>-<xref ref-type="table" rid="table6">6</xref> summarize the key findings of the 26 studies that used MMC to study movement features in people with dementia, MCI, and PD. Stride length, cadence, gait stability, step length, arm swing, and number of steps were the primary features investigated in these studies. Notably, several studies [<xref ref-type="bibr" rid="ref26">26</xref>,<xref ref-type="bibr" rid="ref28">28</xref>,<xref ref-type="bibr" rid="ref33">33</xref>,<xref ref-type="bibr" rid="ref37">37</xref>] found that stride length and cadence are commonly affected in those with PD. Other studies [<xref ref-type="bibr" rid="ref15">15</xref>,<xref ref-type="bibr" rid="ref31">31</xref>,<xref ref-type="bibr" rid="ref38">38</xref>] highlighted the potential of MMC for predicting fall risk and discriminating between individuals with PD and controls.</p>
        <p>Most studies (20/26, 77%) used some form of clinical validation for the assessment of disease, and patients were referred to or assessed within a clinical research facility by a clinician. The most common clinical measures used were the Unified Parkinson’s Disease Rating Scale (UPDRS) for assessing Parkinsonism symptoms in those with PD and dementia and the Performance Oriented Mobility Assessment–gait and Performance Oriented Mobility Assessment–balance assessments for evaluating mobility characteristics. Many of the studies (23/26, 88%) used the MMC features to classify patients from control participants and to classify symptom severity (eg, UPDRS scores in PD) using various techniques, including support vector machines, random forest models, multivariate ordinal logistic regression, and adaptive neuro-fuzzy inference system classifiers. Several studies reported excellent classification accuracy, with some achieving 100% accuracy [<xref ref-type="bibr" rid="ref26">26</xref>,<xref ref-type="bibr" rid="ref27">27</xref>,<xref ref-type="bibr" rid="ref41">41</xref>]. For instance, Seifallahi et al [<xref ref-type="bibr" rid="ref39">39</xref>] achieved an accuracy of over 90% for differentiating between people with MCI and controls using an adaptive neuro-fuzzy inference system classifier. Khan et al [<xref ref-type="bibr" rid="ref26">26</xref>] reported a 70.83% accuracy in predicting UPDRS-gait scores using a support vector machine model, with an area under the receiver operating characteristic curve of 80.88%.</p>
        <p>Conversely, most studies included within this review (20/26, 77%) did not evaluate their MMC system or algorithms against an established gold-standard motion capture model, making it difficult to conclude whether their derived features for monitoring functional performance characteristics were comparable to an accepted measure of movement analysis. Some notable exceptions such as Cimolin et al [<xref ref-type="bibr" rid="ref24">24</xref>] compared their Kinect setup to a Vicon system, which is an accepted and clinically validated method for assessing gait. Other studies used established and clinically validated spatiotemporal measures including the GAITRite system [<xref ref-type="bibr" rid="ref34">34</xref>,<xref ref-type="bibr" rid="ref40">40</xref>] and the Zeno Walkway system [<xref ref-type="bibr" rid="ref37">37</xref>], although the study by Pedro et al [<xref ref-type="bibr" rid="ref34">34</xref>] only had 2 participants. Li et al [<xref ref-type="bibr" rid="ref29">29</xref>] had experts manually annotate videos, which, while subjective, proved effective for creating labels to train machine learning algorithms for task segmentation. They also used automated labeling to generate subtask segmentation, which could help automate larger-scale studies and clinical assessments.</p>
        <p>MMC models showed moderate to strong positive correlations with Vicon [<xref ref-type="bibr" rid="ref24">24</xref>], Zeno [<xref ref-type="bibr" rid="ref37">37</xref>], and GAITRite [<xref ref-type="bibr" rid="ref40">40</xref>]. However, some of the studies also identified limitations of MMC. For example, Pedro et al [<xref ref-type="bibr" rid="ref34">34</xref>] found that Kinect cameras may overestimate step length variation in people with PD due to inherent smoothing, while Sabo et al [<xref ref-type="bibr" rid="ref37">37</xref>] found that automated heel strike algorithms may struggle to identify short steps. Some studies [<xref ref-type="bibr" rid="ref19">19</xref>,<xref ref-type="bibr" rid="ref29">29</xref>] reported challenges with data processing and interpretation, highlighting the need for more standardized methods in this field.</p>
        <p>Despite these limitations, the findings suggest that MMC is a promising tool for studying characteristics of functional performance in people with dementia, MCI, and PD. It is worth noting that specialized depth cameras may not be necessary for extracting suitable joint positions in camera space [<xref ref-type="bibr" rid="ref37">37</xref>]. However, further research in this field is warranted to fully understand the potential of MMC.</p>
        <table-wrap position="float" id="table4">
          <label>Table 4</label>
          <caption>
            <p>Key findings from studies that used the Kinect.</p>
          </caption>
          <table width="1000" cellpadding="5" cellspacing="0" border="1" rules="groups" frame="hsides">
            <col width="130"/>
            <col width="320"/>
            <col width="550"/>
            <thead>
              <tr valign="top">
                <td>Study</td>
                <td>Primary features</td>
                <td>Main results</td>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td>Cimolin et al (2022) [<xref ref-type="bibr" rid="ref24">24</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Gait cadence, mediolateral sway, and step width</p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Strong positive correlation between Kinect and Vicon systems for gait cadence and mediolateral sway (ICC<sup>a</sup> 0.94-0.97) and a weak correlation for step width (ICC 0.44) in people with PD<sup>b</sup></p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Kondragunta et al (2020) [<xref ref-type="bibr" rid="ref19">19</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Gait cycle (dynamic time warping)</p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>SVM<sup>c</sup> for classifying between controls, persons with possible MCI<sup>d</sup>, and persons with MCI: 74.6%-87.3%</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Lai et al (2022) [<xref ref-type="bibr" rid="ref28">28</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Stride length, straight walking speed, and turning speed</p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Mediation analysis demonstrates decreased stride length, walking speed, and turning speed are associated with increased falls prediction model score (<italic>r</italic>=–0.58, <italic>r</italic>=–0.52, and <italic>r</italic>=–0.46, respectively; <italic>P</italic>&lt;.001)</p>
                    </list-item>
                    <list-item>
                      <p>UPDRS<sup>e</sup> negatively correlated with features (<italic>r</italic>=–0.65, <italic>r</italic>=–0.56, and <italic>r</italic>=–0.37, respectively; <italic>P</italic>&lt;.001) but positively with fall prediction model score (<italic>r</italic>=.53, <italic>P</italic>&lt;.001)</p>
                    </list-item>
                    <list-item>
                      <p>UPDRS serves as a mediator for features and higher fall prediction model scores</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Mehdizadeh et al (2021) [<xref ref-type="bibr" rid="ref9">9</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Gait stability, step time, step length, step time variability, and step length variability</p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Mixed effects models over 10 weeks show:</p>
                      <list>
                        <list-item>
                          <p>
                    Decrease in primary features and an increase in variability over time for people with dementia
                  </p>
                        </list-item>
                        <list-item>
                          <p>
                    Gait stability decreased more in men
                  </p>
                        </list-item>
                        <list-item>
                          <p>
                    Mediolateral range of motion decreased in those with mild neuropsychiatric symptoms but increased in those with more severe symptoms
                  </p>
                        </list-item>
                      </list>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Mehdizadeh et al (2021) [<xref ref-type="bibr" rid="ref15">15</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Gait stability.</p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Cox proportional hazard regressions show gait stability predicts time to fall in people with dementia (ROC<sup>f</sup> 0.80 at 7 days, 0.67 at 30 days)</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Muñoz-Ospina et al (2022) [<xref ref-type="bibr" rid="ref31">31</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Left and right arm and ankle swing (magnitude and speed), stance time, gait speed, total time, and number of steps</p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Random forest model was most accurate for discriminating between people with PD and controls (85% using all gait features)</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Ng et al (2020) [<xref ref-type="bibr" rid="ref16">16</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Gait: cadence, symmetry, CV<sup>g</sup> of step time, step width (average and CV), and eMOS<sup>h</sup></p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Univariate linear regression: cadence associated with POMA<sup>i</sup>-gait scores (<italic>P</italic>&lt;.001)</p>
                    </list-item>
                    <list-item>
                      <p>Poisson regression: cadence, eMOS, average step width associated with the number of future falls (<italic>P</italic>&lt;.001)</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Ospina et al (2021) [<xref ref-type="bibr" rid="ref32">32</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Arm swing: magnitude, time, and arm swing asymmetry</p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Age influenced arm movement</p>
                    </list-item>
                    <list-item>
                      <p>People with PD showed significant reductions in arm swing magnitude (left, <italic>P</italic>=.002; right, <italic>P</italic>=.006) and speed (left, <italic>P</italic>=.002; right, <italic>P</italic>=.004)</p>
                    </list-item>
                    <list-item>
                      <p>Arm swing asymmetry differentiated people living with PD from controls (ROC: 78%)</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Otte et al (2020) [<xref ref-type="bibr" rid="ref33">33</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Cadence, knee amplitude, asymmetry, average step time, longest step time, arrhythmicity, average stance time, and longest stance time</p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Knee amplitude and longest stance time correlated with UPDRS (–0.51, <italic>P</italic>=.003 and 0.52, <italic>P</italic>=.002, respectively)</p>
                    </list-item>
                    <list-item>
                      <p>Postural instability (pull test) correlated with longest stance time (0.47, <italic>P</italic>=.008)</p>
                    </list-item>
                    <list-item>
                      <p>Knee amplitude, asymmetry, and average step time differed between on- and off-medication states (<italic>P</italic>=.002, <italic>P</italic>=.007, and <italic>P</italic>=.007, respectively)</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Pedro et al (2020) [<xref ref-type="bibr" rid="ref34">34</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Step length</p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>In comparison with the GAITRite (CIR Systems, Inc) system, the Kinect camera overestimated the average variation in step length for the 2 people with PD potentially due to inherent smoothing</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Procházka et al (2015) [<xref ref-type="bibr" rid="ref35">35</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Average step length</p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>In total, 91.7% classification accuracy for determining between controls and those with people with PD. Decrease in step length (regression coefficient=–0.0082 m/year)</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Sabo et al (2022) [<xref ref-type="bibr" rid="ref18">18</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Number of steps, cadence, velocity, step length, CV of stride width, and step and swing time</p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Moderate or strong positive correlations between steps, cadence, step width from 2D pose-estimation, and Zeno in people with PD</p>
                    </list-item>
                    <list-item>
                      <p>Automated heel strike algorithm struggled to identify short steps</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Sabo et al (2021) [<xref ref-type="bibr" rid="ref17">17</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Cadence, steps, average step width, average margin of stability, CV of step width and time, and symmetry</p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>ST-GCN<sup>j</sup> using 2D joint trajectories and gait features outperforms ST-GCN using only gait features</p>
                    </list-item>
                    <list-item>
                      <p>Regression models for predicting UPDRS-gait over 94% if off by 1 is allowed</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Sabo et al (2020) [<xref ref-type="bibr" rid="ref38">38</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>2D: steps, cadence, symmetry, and CV of step time</p>
                    </list-item>
                    <list-item>
                      <p>3D: walking speed, step length or width, step width, step length symmetry angle, RMS<sup>k</sup> of ML<sup>l</sup> velocity, margin of stability, and CV step width</p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Multivariate ordinal logistic regression models achieved 61.4% and 62.1% for 2D and 3D features for predicting UPDRS-gait in people with dementia</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Seifallahi et al (2022) [<xref ref-type="bibr" rid="ref39">39</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Steps and stride</p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Adaptive neuro-fuzzy inference system classifier accuracy &gt;90% for differentiating between MCI and controls</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Soltaninejad et al (2018) [<xref ref-type="bibr" rid="ref41">41</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Stride and tremor</p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Random forest classifier accuracy for differentiating controls and people with dementia: 93.33% stride and 81% tremor</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Tan et al (2019) [<xref ref-type="bibr" rid="ref42">42</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Step length, step time, vertical pelvic displacement, and gait speed</p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Multivariable regression: step length during TUG<sup>m</sup> and vertical pelvic displacement during the gait speed were associated with postural instability and gait disorder (<italic>P</italic>=.01 and <italic>P</italic>&lt;.05, respectively) in people with PD</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Ťupa et al (2015) [<xref ref-type="bibr" rid="ref43">43</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Step length and average speed</p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Combining gait features improves classification accuracy relative to single features</p>
                    </list-item>
                    <list-item>
                      <p>2-layer neural network achieved an accuracy of 97.2% in classifying people with PD from controls</p>
                    </list-item>
                  </list>
                </td>
              </tr>
            </tbody>
          </table>
          <table-wrap-foot>
            <fn id="table4fn1">
              <p><sup>a</sup>ICC: intraclass correlation coefficient.</p>
            </fn>
            <fn id="table4fn2">
              <p><sup>b</sup>PD: Parkinson disease.</p>
            </fn>
            <fn id="table4fn3">
              <p><sup>c</sup>SVM: support vector machine.</p>
            </fn>
            <fn id="table4fn4">
              <p><sup>d</sup>MCI: mild cognitive impairment.</p>
            </fn>
            <fn id="table4fn5">
              <p><sup>e</sup>UPDRS: Unified Parkinson’s Disease Rating Scale.</p>
            </fn>
            <fn id="table4fn6">
              <p><sup>f</sup>ROC: receiver operating characteristic.</p>
            </fn>
            <fn id="table4fn7">
              <p><sup>g</sup>CV: coefficient of variation.</p>
            </fn>
            <fn id="table4fn8">
              <p><sup>h</sup>eMOS: estimated margin of stability.</p>
            </fn>
            <fn id="table4fn9">
              <p><sup>i</sup>POMA: Tinetti Performance Oriented Mobility Assessment.</p>
            </fn>
            <fn id="table4fn10">
              <p><sup>j</sup>ST-GCN: spatiotemporal graph convolutional networks.</p>
            </fn>
            <fn id="table4fn11">
              <p><sup>k</sup>RMS: root mean squared.</p>
            </fn>
            <fn id="table4fn12">
              <p><sup>l</sup>ML: mediolateral.</p>
            </fn>
            <fn id="table4fn13">
              <p><sup>m</sup>TUG: Timed Up and Go.</p>
            </fn>
          </table-wrap-foot>
        </table-wrap>
        <table-wrap position="float" id="table5">
          <label>Table 5</label>
          <caption>
            <p>Key findings from studies that used video cameras.</p>
          </caption>
          <table width="1000" cellpadding="5" cellspacing="0" border="1" rules="groups" frame="hsides">
            <col width="126"/>
            <col width="314"/>
            <col width="560"/>
            <thead>
              <tr valign="top">
                <td>Study</td>
                <td>Primary features</td>
                <td>Main results</td>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td>Kaur et al (2023) [<xref ref-type="bibr" rid="ref25">25</xref>]</td>
                <td>Stride (91 derived features based on variation and asymmetry speed)</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Logistic regression, random forest, deep learning–based classifiers 75% (walking and talking) and 78.1% (walking)</p>
                    </list-item>
                    <list-item>
                      <p>Multi-scale residual neural network: 100% accuracy for classifying people with controls, multiple sclerosis, and people with PD<sup>a</sup> during walking and walking-while-talking, and 78% for new subjects walking</p>
                    </list-item>
                    <list-item>
                      <p>1D convolutional neural network: 75% walking-while-talking and 79.3% when generalizing to new subjects in different tasks</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Khan et al (2021) [<xref ref-type="bibr" rid="ref26">26</xref>]</td>
                <td>Slow walking short-shuffling steps gait festination</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>SVM<sup>b</sup> classification predicts UPDRS<sup>c</sup>: gait scores with 70.83% accuracy and area under ROC<sup>d</sup> curve 80.88%</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Khan et al (2013) [<xref ref-type="bibr" rid="ref27">27</xref>]</td>
                <td>Stride cycles and posture lean</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>SVM classification of 100% for differentiating between people with PD and controls</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Li et al (2018) [<xref ref-type="bibr" rid="ref29">29</xref>]</td>
                <td>Subtask segmentation based on selected body points: neck, R/L<sup>e</sup> shoulder, R/L hip, R/L knee, or R/L ankle</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Accuracies for subtask segmentation of TUGg: OpenPose+LSTM<sup>f</sup>=93.10% and OpenPose+LSTM=92.8%</p>
                    </list-item>
                    <list-item>
                      <p>Correlations between OpenPose+LSTM and experts on timed reduction rates: turn (0.93), walk-back (0.98), and sit-back (0.98)</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Sabo et al (2022) [<xref ref-type="bibr" rid="ref37">37</xref>]</td>
                <td>Cadence, steps, average step width, average margin of stability, CV<sup>g</sup> of step width and time, symmetry, and stability</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>ST-GCN<sup>h</sup> operating on 3D joint trajectories outperform 2D models</p>
                    </list-item>
                    <list-item>
                      <p>Best model prediction of UPDRS-gait and SAS<sup>i</sup>-gait scores are 53% and 40%, respectively.</p>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Shin et al (2021) [<xref ref-type="bibr" rid="ref40">40</xref>]</td>
                <td>Step length, gait velocity, number of steps, and turning time</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Features correlated with Freezing of Gait Questionnaire, UPDRS part III total score, HY<sup>j</sup>, and postural instability in people with PD</p>
                    </list-item>
                    <list-item>
                      <p>Features measured improvements following medication</p>
                    </list-item>
                  </list>
                </td>
              </tr>
            </tbody>
          </table>
          <table-wrap-foot>
            <fn id="table5fn1">
              <p><sup>a</sup>PD: Parkinson disease.</p>
            </fn>
            <fn id="table5fn2">
              <p><sup>b</sup>SVM: support vector machine.</p>
            </fn>
            <fn id="table5fn3">
              <p><sup>c</sup>UPDRS: Unified Parkinson’s Disease Rating Scale.</p>
            </fn>
            <fn id="table5fn4">
              <p><sup>d</sup>ROC: receiver operating characteristic.</p>
            </fn>
            <fn id="table5fn5">
              <p><sup>e</sup>R/L: right or left.</p>
            </fn>
            <fn id="table5fn6">
              <p><sup>f</sup>LSTM: long short-term memory (machine learning model).</p>
            </fn>
            <fn id="table5fn7">
              <p><sup>g</sup>CV: coefficient of variation.</p>
            </fn>
            <fn id="table5fn8">
              <p><sup>h</sup>ST-GCN: spatiotemporal graph convolutional networks.</p>
            </fn>
            <fn id="table5fn9">
              <p><sup>i</sup>SAS: Simpson-Angus Scale.</p>
            </fn>
            <fn id="table5fn10">
              <p><sup>j</sup>HY: Hoehn and Yahr scale.</p>
            </fn>
          </table-wrap-foot>
        </table-wrap>
        <table-wrap position="float" id="table6">
          <label>Table 6</label>
          <caption>
            <p>Key findings from studies that used mobile phone cameras.</p>
          </caption>
          <table width="1000" cellpadding="5" cellspacing="0" border="1" rules="groups" frame="hsides">
            <col width="126"/>
            <col width="314"/>
            <col width="560"/>
            <thead>
              <tr valign="top">
                <td>Study</td>
                <td>Primary features</td>
                <td>Main results</td>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td>Morinan et al (2022) [<xref ref-type="bibr" rid="ref30">30</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p><italic>D<sub>body</sub></italic>: distance between nose and 2 ankles</p>
                    </list-item>
                    <list-item>
                      <p>Standard of <italic>D<sub>body</sub></italic>, proportional increase in <italic>D<sub>body</sub></italic>, and percentage jerk of <italic>D<sub>body</sub></italic></p>
                    </list-item>
                  </list>
                  <list list-type="bullet">
                    <list-item>
                      <p><italic>D<sub>hand</sub></italic>: distance between 2 wrists</p>
                    </list-item>
                    <list-item>
                      <p>U: hands used (Boolean)</p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Ordinal random forest classifiers:</p>
                      <list>
                        <list-item>
                          <p>
                    U=99.6% accuracy for hands used to push up from chair
                  </p>
                        </list-item>
                        <list-item>
                          <p>
                    UPDRS<sup>a</sup> ratings estimated by models agree by 79.2% with clinicians’ ratings for people with PD<sup>b</sup>
                  </p>
                        </list-item>
                      </list>
                    </list-item>
                  </list>
                </td>
              </tr>
              <tr valign="top">
                <td>Rupprechter et al (2021) [<xref ref-type="bibr" rid="ref36">36</xref>]</td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Steps, arm swing, postural control, and smoothness</p>
                    </list-item>
                  </list>
                </td>
                <td>
                  <list list-type="bullet">
                    <list-item>
                      <p>Step frequency highly correlated with labeled steps (<italic>P</italic>&lt;.001)</p>
                    </list-item>
                    <list-item>
                      <p>Ordinal random forest: 50% prediction</p>
                    </list-item>
                  </list>
                </td>
              </tr>
            </tbody>
          </table>
          <table-wrap-foot>
            <fn id="table6fn1">
              <p><sup>a</sup>UPDRS: Unified Parkinson’s Disease Rating Scale.</p>
            </fn>
            <fn id="table6fn2">
              <p><sup>b</sup>PD: Parkinson disease.</p>
            </fn>
          </table-wrap-foot>
        </table-wrap>
      </sec>
    </sec>
    <sec sec-type="discussion">
      <title>Discussion</title>
      <sec>
        <title>Principal Findings</title>
        <p>This systematic review has shown that there is a paucity of studies exploring the use of MMC in people with dementia and models exploring the performance of ADL. Moreover, there is a lack of standardization in the used MMC models and clinical validation in real-world applications. The absence of standardization among the models used posed a significant challenge, precluding the possibility of conducting a meta-analysis to compare and synthesize study results.</p>
        <p>The review findings suggest that there is more evidence of the use of MMC with full-body tracking in patients with PD (n=18) compared to those with dementia (n=6) and MCI (n=2). This demonstrates a bias toward movement disorders, where the motor symptoms are more prominent, and highlights a significant knowledge gap in the feasibility and effectiveness of using MMC models in quantifying functional performance in people with dementia and MCI. Moreover, the studies that included patients with dementia [<xref ref-type="bibr" rid="ref9">9</xref>,<xref ref-type="bibr" rid="ref15">15</xref>-<xref ref-type="bibr" rid="ref18">18</xref>,<xref ref-type="bibr" rid="ref38">38</xref>] were all conducted in inpatient dementia units, indicating a lack of research involving this patient group in real-world settings. This underscores the need for further investigation in this area.</p>
        <p>While MMC models based on gait features extracted mainly from straight-line walking may provide useful preliminary data for model development, they have less scope in quantifying functional performance in a real-world context, particularly in people with cognitive impairment. In contrast, the evaluation of ADL tasks could potentially provide more comprehensive insights into real-world functional performance from routine daily activities. Previous research suggests that dual-task tests of mobility are more effective in detecting cognitive decline as well as predicting cognitive impairment and falls [<xref ref-type="bibr" rid="ref44">44</xref>-<xref ref-type="bibr" rid="ref46">46</xref>], potentially due to the increased cognitive demand on the individual. However, just 1 study included in this review [<xref ref-type="bibr" rid="ref19">19</xref>] used dual tasks for the classification of MCI from control, and it was not reported how the completion of dual tasks impacted the results. Feature extraction of ADL tasks that require planning and organization could potentially facilitate the measurement of dual-task performance. Therefore, analysis of ADL tasks could help provide a more accurate assessment of neurodegenerative impairment.</p>
        <p>The findings of this review suggest a lack of consensus on the most effective features used. Some spatiotemporal features of mobility such as step length are commonly used, but other features vary widely between studies, making it difficult to determine which are most effective. Additionally, some unique features such as vertical pelvic displacement [<xref ref-type="bibr" rid="ref42">42</xref>] and <italic>D<sub>body</sub>,</italic> the distance between nose and 2 ankles [<xref ref-type="bibr" rid="ref30">30</xref>], have been identified in individual studies, but their effectiveness is unknown without further evaluation. Moreover, it is important to note that the effectiveness of several of these feature extraction models has not been tested in real-world settings which therefore requires further evaluation.</p>
        <p>Several studies included in the review (n=10) reported machine learning classifier outcomes for identifying people living with dementia, MCI, or PD from control [<xref ref-type="bibr" rid="ref19">19</xref>,<xref ref-type="bibr" rid="ref25">25</xref>-<xref ref-type="bibr" rid="ref27">27</xref>,<xref ref-type="bibr" rid="ref31">31</xref>,<xref ref-type="bibr" rid="ref32">32</xref>,<xref ref-type="bibr" rid="ref35">35</xref>,<xref ref-type="bibr" rid="ref39">39</xref>,<xref ref-type="bibr" rid="ref41">41</xref>,<xref ref-type="bibr" rid="ref43">43</xref>], whereas several others (n=8) reported models that computed clinical assessment scores [<xref ref-type="bibr" rid="ref17">17</xref>,<xref ref-type="bibr" rid="ref18">18</xref>,<xref ref-type="bibr" rid="ref29">29</xref>,<xref ref-type="bibr" rid="ref30">30</xref>,<xref ref-type="bibr" rid="ref33">33</xref>,<xref ref-type="bibr" rid="ref36">36</xref>,<xref ref-type="bibr" rid="ref38">38</xref>,<xref ref-type="bibr" rid="ref40">40</xref>]. Although these are useful outcomes, it is important to note that models that help detect gait impairment and predict falls (n=5) [<xref ref-type="bibr" rid="ref9">9</xref>,<xref ref-type="bibr" rid="ref15">15</xref>,<xref ref-type="bibr" rid="ref16">16</xref>,<xref ref-type="bibr" rid="ref28">28</xref>,<xref ref-type="bibr" rid="ref42">42</xref>] could potentially be more useful in practical applications for assessing functional performance. It must also be noted that these models were all based on the Kinect cameras demonstrating the potential of RGB-D cameras for detecting and predicting functional impairment.</p>
        <p>Accurate feature extraction and classification are crucial for improving the quality of MMC-based functional assessment [<xref ref-type="bibr" rid="ref47">47</xref>]. The accuracy rates of MMC models reported in the reviewed studies ranged from 40% for a model predicting a clinical assessment score [<xref ref-type="bibr" rid="ref18">18</xref>] to 100% for machine learning classification of PD from control [<xref ref-type="bibr" rid="ref27">27</xref>]. Those numbers cannot be compared directly due to the different number of classes and the resulting chance level, as well as the task difficulty between classifying patients from control participants to rating symptoms. However, it is important to ensure that any clinical applications of these models are consistent and accurate because inaccurate predictions could potentially have consequences for patient care. Further validation and refinement of the models may therefore be necessary before they can be safely used in practical applications.</p>
        <p>It is important to note that the accuracy of a model does not only depend on its ability to correctly identify a condition but also on its capacity to detect features of functional performance consistently in various real-world settings. Potential real-world applications include the detection of problems in functional performance in clinical settings and functional deterioration in home settings. The effectiveness of several feature extraction models reviewed in this study has not been tested in such settings, and therefore, the accuracy in practical applications remains unclear. Moreover, devices used in clinical applications must be subjected to a rigorous clinical validation process to ensure safety and efficacy before use on patients [<xref ref-type="bibr" rid="ref48">48</xref>]. Many of the studies reviewed seem to have primarily focused on the technical aspects of the MMC models, such as feature extraction and analysis, with less focus on their clinical utility. Therefore, further MMC research should objectively evaluate the practical clinical and real-world mobility applications of this technology. If a standard MMC movement analysis protocol could be established, functional performance could be compared across diagnoses.</p>
        <p>Additionally, the cross-sectional nature of most of the included studies may limit their ability to evaluate and track functional performance over time. Longitudinal studies would be necessary to assess the performance of these models for tracking functional changes caused by factors such as disease progression, infections, and treatment effects or recovery. Despite these limitations, the effectiveness of MMC models using the Kinect [<xref ref-type="bibr" rid="ref24">24</xref>] and 2D pose estimation [<xref ref-type="bibr" rid="ref37">37</xref>] in comparison to established gold-standard motion capture systems within experimental settings suggests they may be suitable for testing in real-world applications such as remote monitoring. However, further research is required to explore and address ethical and privacy considerations when deploying MMC devices that capture video and movement within people’s homes. Managing consent where patients lack mental capacity and safeguarding the privacy of patient data that is stored or shared with clinical teams will also need to be carefully addressed while deploying MMC in remote monitoring applications.</p>
        <p>It is important to consider the overall quality of studies included in this review, as shown in <xref ref-type="table" rid="table1">Table 1</xref>, which summarizes key questions to consider when assessing quality. Most studies had a clear study design and focused research questions with appropriate measures of exposures and outcomes. However, only 1 of the studies reported if potential sources of bias from confounders such as musculoskeletal comorbidities, were controlled which could have significant implications for clinical applications. Moreover, few studies provided information on participant eligibility and whether they were selected fairly which could have implications for generalization of study results. The suboptimal quality observed in the included studies in key aspects such as bias control and participant selection suggests these MMC models need to be further evaluated potentially using more rigorous study designs before deployment in real-world applications. Studies that have attempted to create MMC models for fall prediction have primarily focused on retrospective analyses, for example, the number of falls in the past few months. While it is useful to examine historical patterns, future studies should aim to develop prospective studies. Testing the algorithms for MMC models in a prospective study would offer the capability to analyze more detailed information on fall events and contextual associated factors therefore making them more generalizable and valid for predicting falls.</p>
        <p>The main findings of this review highlight the potential of MMC in assessing components of functional performance including gait and sit-to-stand characteristics in individuals with dementia, MCI, and PD. Notably, high classification accuracies in several studies demonstrate the potential for clinical applications, such as identifying, monitoring, and predicting outcomes in these populations. However, it is crucial to address the limitations and challenges, such as overestimation of step length variation and difficulty in identifying short steps, as well as the need for standardized methodologies and further research.</p>
        <p>A segment of motion analysis research will likely continue to focus on simplified, discrete tasks executed within the controlled setting of a laboratory. However, advancements in technology are progressively enabling the expansion of movement analysis into real-world environments [<xref ref-type="bibr" rid="ref49">49</xref>]. While the current body of literature predominantly centers on gait analysis, the potential applications of MMC extend far beyond this domain, particularly within the realm of ADL. The integration of knowledge gleaned from analyzing various types of functional tasks will empower clinicians to better assist individuals with neurodegeneration in enhancing their quality of life.</p>
      </sec>
      <sec>
        <title>Limitations</title>
        <p>It was not feasible to conduct a meta-analysis of the reviewed studies due to significant heterogeneity in the MMC models evaluated, the features extracted, and the analysis methods used. The use of search terms that are not specific to MMC such as motion capture and movement analysis may have introduced the possibility of inherent biases in the search results. However, the adoption of these broad search terms facilitated a more comprehensive screening of studies, encompassing a wider spectrum of the literature. Furthermore, it is important to acknowledge a potential constraint inherent in the search strategy, specifically about the inclusion criterion of full-body tracking MMC models. This led to the exclusion of studies that analyzed the movement of specific body parts. Another limitation of this review is that only a small number of studies met the inclusion criteria limiting the generalizability of this study’s results.</p>
      </sec>
      <sec>
        <title>Conclusion</title>
        <p>The findings of this review illustrate that the use of MMC technology with full-body tracking has the potential to quantify functional performance in people living with dementia, MCI, and PD. However, the lack of consistency in evaluating these models presents a challenge. Standardization of the extracted features and analysis methods may help overcome the heterogeneity of the evaluation process and propose a framework for assessing future models. The findings further suggest that MMC models based on both RGB-D and standard video cameras are viable options for analyzing movement, yielding similar outcomes. Nonetheless, RGB-D cameras have been favored in models intended to detect gait impairment and predict instances of falling.</p>
        <p>It is worth noting that the majority of the reviewed studies evaluated aspects of gait, with no evidence of ADL tasks being analyzed. Future studies should incorporate ADL tasks, as this would be more representative of real-world scenarios, particularly for individuals with cognitive impairment. Moreover, longitudinal studies are required to develop models that could track functional impairment over time and potentially predict decline.</p>
        <p>Although accuracy is an important factor to consider when evaluating MMC models for clinical applications, other factors such as comparability to established gold-standard motion capture models and capability for analyzing routine tasks and reproducibility in the natural environment are also important. Therefore, a more holistic approach to model development and evaluation with a clear focus on real-world clinical utility may be necessary to ensure that the models are suitable for use in practical applications.</p>
      </sec>
    </sec>
  </body>
  <back>
    <app-group>
      <supplementary-material id="app1">
        <label>Multimedia Appendix 1</label>
        <p>Search activity record.</p>
        <media xlink:href="aging_v7i1e52582_app1.docx" xlink:title="DOCX File , 38 KB"/>
      </supplementary-material>
    </app-group>
    <glossary>
      <title>Abbreviations</title>
      <def-list>
        <def-item>
          <term id="abb1">ADL</term>
          <def>
            <p>activities of daily living</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb2">MCI</term>
          <def>
            <p>mild cognitive impairment</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb3">MMC</term>
          <def>
            <p>markerless motion capture</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb4">PD</term>
          <def>
            <p>Parkinson disease</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb5">PRISMA</term>
          <def>
            <p>Preferred Reporting Items for Systematic Reviews and Meta-Analyses</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb6">RGB</term>
          <def>
            <p>red-green-blue</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb7">RGB-D</term>
          <def>
            <p>red-green-blue+depth</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb8">UPDRS</term>
          <def>
            <p>Unified Parkinson’s Disease Rating Scale</p>
          </def>
        </def-item>
      </def-list>
    </glossary>
    <ack>
      <p>This study was supported by the UK Dementia Research Institute, Care Research &amp; Technology Centre. JJ-J’s research fellowship is funded by the Imperial Health Charity and the National Institute for Health and Care Research Imperial Biomedical Research Centre. SH is supported by the Edmond and Lily Safra Fellowship.</p>
    </ack>
    <notes>
      <sec>
        <title>Data Availability</title>
        <p>No new or unpublished data are included within this study and all data are freely available. All code relating to summary figure development is available on request to the corresponding authors.</p>
      </sec>
    </notes>
    <fn-group>
      <fn fn-type="con">
        <p>JJ-J and SH wrote the review protocol, JJ-J, MC-R, HS, and TJ conducted the literature searches and performed data extraction. JJ-J, MC-R, and SH wrote this paper. All authors read and critically commented on drafts of this study, including the latest version.</p>
      </fn>
      <fn fn-type="conflict">
        <p>None declared.</p>
      </fn>
    </fn-group>
    <ref-list>
      <ref id="ref1">
        <label>1</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Mentiplay</surname>
              <given-names>BF</given-names>
            </name>
            <name name-style="western">
              <surname>Perraton</surname>
              <given-names>LG</given-names>
            </name>
            <name name-style="western">
              <surname>Bower</surname>
              <given-names>KJ</given-names>
            </name>
            <name name-style="western">
              <surname>Pua</surname>
              <given-names>YH</given-names>
            </name>
            <name name-style="western">
              <surname>McGaw</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Heywood</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Clark</surname>
              <given-names>RA</given-names>
            </name>
          </person-group>
          <article-title>Gait assessment using the Microsoft Xbox One Kinect: concurrent validity and inter-day reliability of spatiotemporal and kinematic variables</article-title>
          <source>J Biomech</source>
          <year>2015</year>
          <volume>48</volume>
          <issue>10</issue>
          <fpage>2166</fpage>
          <lpage>2170</lpage>
          <pub-id pub-id-type="doi">10.1016/j.jbiomech.2015.05.021</pub-id>
          <pub-id pub-id-type="medline">26065332</pub-id>
          <pub-id pub-id-type="pii">S0021-9290(15)00298-5</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref2">
        <label>2</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Vernon</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Paterson</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Bower</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>McGinley</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Miller</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Pua</surname>
              <given-names>YH</given-names>
            </name>
            <name name-style="western">
              <surname>Clark</surname>
              <given-names>RA</given-names>
            </name>
          </person-group>
          <article-title>Quantifying individual components of the Timed Up and Go using the Kinect in people living with stroke</article-title>
          <source>Neurorehabil Neural Repair</source>
          <year>2015</year>
          <volume>29</volume>
          <issue>1</issue>
          <fpage>48</fpage>
          <lpage>53</lpage>
          <pub-id pub-id-type="doi">10.1177/1545968314529475</pub-id>
          <pub-id pub-id-type="medline">24743227</pub-id>
          <pub-id pub-id-type="pii">1545968314529475</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref3">
        <label>3</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Clark</surname>
              <given-names>RA</given-names>
            </name>
            <name name-style="western">
              <surname>Pua</surname>
              <given-names>YH</given-names>
            </name>
            <name name-style="western">
              <surname>Oliveira</surname>
              <given-names>CC</given-names>
            </name>
            <name name-style="western">
              <surname>Bower</surname>
              <given-names>KJ</given-names>
            </name>
            <name name-style="western">
              <surname>Thilarajah</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>McGaw</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Hasanki</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Mentiplay</surname>
              <given-names>BF</given-names>
            </name>
          </person-group>
          <article-title>Reliability and concurrent validity of the Microsoft Xbox One Kinect for assessment of standing balance and postural control</article-title>
          <source>Gait Posture</source>
          <year>2015</year>
          <volume>42</volume>
          <issue>2</issue>
          <fpage>210</fpage>
          <lpage>213</lpage>
          <pub-id pub-id-type="doi">10.1016/j.gaitpost.2015.03.005</pub-id>
          <pub-id pub-id-type="medline">26009500</pub-id>
          <pub-id pub-id-type="pii">S0966-6362(15)00074-0</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref4">
        <label>4</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Ma</surname>
              <given-names>Y</given-names>
            </name>
            <name name-style="western">
              <surname>Liu</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Cai</surname>
              <given-names>L</given-names>
            </name>
          </person-group>
          <article-title>Deep learning-based upper limb functional assessment using a single Kinect v2 sensor</article-title>
          <source>Sensors (Basel)</source>
          <year>2020</year>
          <volume>20</volume>
          <issue>7</issue>
          <fpage>1903</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.mdpi.com/resolver?pii=s20071903"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/s20071903</pub-id>
          <pub-id pub-id-type="medline">32235436</pub-id>
          <pub-id pub-id-type="pii">s20071903</pub-id>
          <pub-id pub-id-type="pmcid">PMC7180801</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref5">
        <label>5</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Rammer</surname>
              <given-names>JR</given-names>
            </name>
            <name name-style="western">
              <surname>Krzak</surname>
              <given-names>JJ</given-names>
            </name>
            <name name-style="western">
              <surname>Riedel</surname>
              <given-names>SA</given-names>
            </name>
            <name name-style="western">
              <surname>Harris</surname>
              <given-names>GF</given-names>
            </name>
          </person-group>
          <article-title>Evaluation of upper extremity movement characteristics during standardized pediatric functional assessment with a Kinect®-based markerless motion analysis system</article-title>
          <source>Annu Int Conf IEEE Eng Med Biol Soc</source>
          <year>2014</year>
          <volume>2014</volume>
          <fpage>2525</fpage>
          <lpage>2528</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://europepmc.org/abstract/MED/25570504"/>
          </comment>
          <pub-id pub-id-type="doi">10.1109/EMBC.2014.6944136</pub-id>
          <pub-id pub-id-type="medline">25570504</pub-id>
          <pub-id pub-id-type="pmcid">PMC4479272</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref6">
        <label>6</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Klöpfer-Krämer</surname>
              <given-names>I</given-names>
            </name>
            <name name-style="western">
              <surname>Brand</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Wackerle</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Müßig</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Kröger</surname>
              <given-names>I</given-names>
            </name>
            <name name-style="western">
              <surname>Augat</surname>
              <given-names>P</given-names>
            </name>
          </person-group>
          <article-title>Gait analysis—available platforms for outcome assessment</article-title>
          <source>Injury</source>
          <year>2020</year>
          <volume>51 Suppl 2</volume>
          <fpage>S90</fpage>
          <lpage>S96</lpage>
          <pub-id pub-id-type="doi">10.1016/j.injury.2019.11.011</pub-id>
          <pub-id pub-id-type="medline">31767371</pub-id>
          <pub-id pub-id-type="pii">S0020-1383(19)30708-9</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref7">
        <label>7</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Bonnechère</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Jansen</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Salvia</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Bouzahouene</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Omelina</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Moiseev</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Sholukha</surname>
              <given-names>V</given-names>
            </name>
            <name name-style="western">
              <surname>Cornelis</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Rooze</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>van Sint Jan</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
          <article-title>Validity and reliability of the Kinect within functional assessment activities: comparison with standard stereophotogrammetry</article-title>
          <source>Gait Posture</source>
          <year>2014</year>
          <volume>39</volume>
          <issue>1</issue>
          <fpage>593</fpage>
          <lpage>598</lpage>
          <pub-id pub-id-type="doi">10.1016/j.gaitpost.2013.09.018</pub-id>
          <pub-id pub-id-type="medline">24269523</pub-id>
          <pub-id pub-id-type="pii">S0966-6362(13)00631-0</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref8">
        <label>8</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>van Dellen</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Hesse</surname>
              <given-names>N</given-names>
            </name>
            <name name-style="western">
              <surname>Labruyère</surname>
              <given-names>R</given-names>
            </name>
          </person-group>
          <article-title>Markerless motion tracking to quantify behavioral changes during robot-assisted gait training: a validation study</article-title>
          <source>Front Robot AI</source>
          <year>2023</year>
          <volume>10</volume>
          <fpage>1155542</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://europepmc.org/abstract/MED/36950282"/>
          </comment>
          <pub-id pub-id-type="doi">10.3389/frobt.2023.1155542</pub-id>
          <pub-id pub-id-type="medline">36950282</pub-id>
          <pub-id pub-id-type="pii">1155542</pub-id>
          <pub-id pub-id-type="pmcid">PMC10025461</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref9">
        <label>9</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Mehdizadeh</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Faieghi</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Sabo</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Nabavi</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Mansfield</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Flint</surname>
              <given-names>AJ</given-names>
            </name>
            <name name-style="western">
              <surname>Taati</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Iaboni</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
          <article-title>Gait changes over time in hospitalized older adults with advanced dementia: predictors of mobility change</article-title>
          <source>PLoS One</source>
          <year>2021</year>
          <volume>16</volume>
          <issue>11</issue>
          <fpage>e0259975</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://dx.plos.org/10.1371/journal.pone.0259975"/>
          </comment>
          <pub-id pub-id-type="doi">10.1371/journal.pone.0259975</pub-id>
          <pub-id pub-id-type="medline">34788342</pub-id>
          <pub-id pub-id-type="pii">PONE-D-21-08253</pub-id>
          <pub-id pub-id-type="pmcid">PMC8598066</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref10">
        <label>10</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Wade</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Needham</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>McGuigan</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Bilzon</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
          <article-title>Applications and limitations of current markerless motion capture methods for clinical gait biomechanics</article-title>
          <source>PeerJ</source>
          <year>2022</year>
          <volume>10</volume>
          <fpage>e12995</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://europepmc.org/abstract/MED/35237469"/>
          </comment>
          <pub-id pub-id-type="doi">10.7717/peerj.12995</pub-id>
          <pub-id pub-id-type="medline">35237469</pub-id>
          <pub-id pub-id-type="pii">12995</pub-id>
          <pub-id pub-id-type="pmcid">PMC8884063</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref11">
        <label>11</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Nakano</surname>
              <given-names>N</given-names>
            </name>
            <name name-style="western">
              <surname>Sakura</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Ueda</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Omura</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Kimura</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Iino</surname>
              <given-names>Y</given-names>
            </name>
            <name name-style="western">
              <surname>Fukashiro</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Yoshioka</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
          <article-title>Evaluation of 3D markerless motion capture accuracy using OpenPose with multiple video cameras</article-title>
          <source>Front Sports Act Living</source>
          <year>2020</year>
          <volume>2</volume>
          <fpage>50</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://europepmc.org/abstract/MED/33345042"/>
          </comment>
          <pub-id pub-id-type="doi">10.3389/fspor.2020.00050</pub-id>
          <pub-id pub-id-type="medline">33345042</pub-id>
          <pub-id pub-id-type="pmcid">PMC7739760</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref12">
        <label>12</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Scott</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Seyres</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Philp</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Chadwick</surname>
              <given-names>EK</given-names>
            </name>
            <name name-style="western">
              <surname>Blana</surname>
              <given-names>D</given-names>
            </name>
          </person-group>
          <article-title>Healthcare applications of single camera markerless motion capture: a scoping review</article-title>
          <source>PeerJ</source>
          <year>2022</year>
          <volume>10</volume>
          <fpage>e13517</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://europepmc.org/abstract/MED/35642200"/>
          </comment>
          <pub-id pub-id-type="doi">10.7717/peerj.13517</pub-id>
          <pub-id pub-id-type="medline">35642200</pub-id>
          <pub-id pub-id-type="pii">13517</pub-id>
          <pub-id pub-id-type="pmcid">PMC9148557</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref13">
        <label>13</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Knippenberg</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>Verbrugghe</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Lamers</surname>
              <given-names>I</given-names>
            </name>
            <name name-style="western">
              <surname>Palmaers</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Timmermans</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Spooren</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
          <article-title>Markerless motion capture systems as training device in neurological rehabilitation: a systematic review of their use, application, target population and efficacy</article-title>
          <source>J Neuroeng Rehabil</source>
          <year>2017</year>
          <volume>14</volume>
          <issue>1</issue>
          <fpage>61</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://jneuroengrehab.biomedcentral.com/articles/10.1186/s12984-017-0270-x"/>
          </comment>
          <pub-id pub-id-type="doi">10.1186/s12984-017-0270-x</pub-id>
          <pub-id pub-id-type="medline">28646914</pub-id>
          <pub-id pub-id-type="pii">10.1186/s12984-017-0270-x</pub-id>
          <pub-id pub-id-type="pmcid">PMC5482943</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref14">
        <label>14</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Lam</surname>
              <given-names>WWT</given-names>
            </name>
            <name name-style="western">
              <surname>Fong</surname>
              <given-names>KNK</given-names>
            </name>
          </person-group>
          <article-title>The application of markerless motion capture (MMC) technology in rehabilitation programs: a systematic review and meta-analysis</article-title>
          <source>Virtual Real</source>
          <year>2022</year>
          <volume>27</volume>
          <issue>4</issue>
          <fpage>3363</fpage>
          <lpage>3378</lpage>
          <pub-id pub-id-type="doi">10.1007/s10055-022-00696-6</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref15">
        <label>15</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Mehdizadeh</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Sabo</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Ng</surname>
              <given-names>KD</given-names>
            </name>
            <name name-style="western">
              <surname>Mansfield</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Flint</surname>
              <given-names>AJ</given-names>
            </name>
            <name name-style="western">
              <surname>Taati</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Iaboni</surname>
              <given-names>A</given-names>
            </name>
          </person-group>
          <article-title>Predicting short-term risk of falls in a high-risk group with dementia</article-title>
          <source>J Am Med Dir Assoc</source>
          <year>2021</year>
          <volume>22</volume>
          <issue>3</issue>
          <fpage>689</fpage>
          <lpage>695</lpage>
          <pub-id pub-id-type="doi">10.1016/j.jamda.2020.07.030</pub-id>
          <pub-id pub-id-type="medline">32900610</pub-id>
          <pub-id pub-id-type="pii">S1525-8610(20)30655-1</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref16">
        <label>16</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Ng</surname>
              <given-names>KD</given-names>
            </name>
            <name name-style="western">
              <surname>Mehdizadeh</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Iaboni</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Mansfield</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Flint</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Taati</surname>
              <given-names>B</given-names>
            </name>
          </person-group>
          <article-title>Measuring gait variables using computer vision to assess mobility and fall risk in older adults with dementia</article-title>
          <source>IEEE J Transl Eng Health Med</source>
          <year>2020</year>
          <volume>8</volume>
          <fpage>1</fpage>
          <lpage>9</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://europepmc.org/abstract/MED/32537265"/>
          </comment>
          <pub-id pub-id-type="doi">10.1109/JTEHM.2020.2998326</pub-id>
          <pub-id pub-id-type="medline">32537265</pub-id>
          <pub-id pub-id-type="pii">2100609</pub-id>
          <pub-id pub-id-type="pmcid">PMC7289176</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref17">
        <label>17</label>
        <nlm-citation citation-type="confproc">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Sabo</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Mehdizadeh</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Iaboni</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Taati</surname>
              <given-names>B</given-names>
            </name>
          </person-group>
          <article-title>Prediction of parkinsonian gait in older adults with dementia using joint trajectories and gait features from 2D video</article-title>
          <year>2021</year>
          <conf-name>2021 43rd Annual International Conference of the IEEE Engineering in Medicine &amp; Biology Society (EMBC) IEEE; 2021.?5703</conf-name>
          <conf-date>2021 Nov 01</conf-date>
          <conf-loc>Mexico</conf-loc>
          <publisher-name>IEEE</publisher-name>
          <fpage>5700</fpage>
          <lpage>5703</lpage>
          <pub-id pub-id-type="doi">10.1109/embc46164.2021.9630563</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref18">
        <label>18</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Sabo</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Mehdizadeh</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Iaboni</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Taati</surname>
              <given-names>B</given-names>
            </name>
          </person-group>
          <article-title>Estimating parkinsonism severity in natural gait videos of older adults with dementia</article-title>
          <source>IEEE J Biomed Health Inform</source>
          <year>2022</year>
          <volume>26</volume>
          <issue>5</issue>
          <fpage>2288</fpage>
          <lpage>2298</lpage>
          <pub-id pub-id-type="doi">10.1109/JBHI.2022.3144917</pub-id>
          <pub-id pub-id-type="medline">35077373</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref19">
        <label>19</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Kondragunta</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Seidel</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Hirtz</surname>
              <given-names>G</given-names>
            </name>
          </person-group>
          <article-title>Machine learning based identification of elderly persons with cognitive impairment using dynamic time warping</article-title>
          <source>Current Directions in Biomedical Engineering</source>
          <year>2020</year>
          <volume>6</volume>
          <issue>3</issue>
          <fpage>360</fpage>
          <lpage>363</lpage>
          <pub-id pub-id-type="doi">10.1515/cdbme-2020-3093</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref20">
        <label>20</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Graff</surname>
              <given-names>MJL</given-names>
            </name>
            <name name-style="western">
              <surname>Vernooij-Dassen</surname>
              <given-names>MJM</given-names>
            </name>
            <name name-style="western">
              <surname>Thijssen</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Dekker</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Hoefnagels</surname>
              <given-names>WHL</given-names>
            </name>
            <name name-style="western">
              <surname>Rikkert</surname>
              <given-names>MGMO</given-names>
            </name>
          </person-group>
          <article-title>Community based occupational therapy for patients with dementia and their care givers: randomised controlled trial</article-title>
          <source>BMJ</source>
          <year>2006</year>
          <volume>333</volume>
          <issue>7580</issue>
          <fpage>1196</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://europepmc.org/abstract/MED/17114212"/>
          </comment>
          <pub-id pub-id-type="doi">10.1136/bmj.39001.688843.BE</pub-id>
          <pub-id pub-id-type="medline">17114212</pub-id>
          <pub-id pub-id-type="pii">bmj.39001.688843.BE</pub-id>
          <pub-id pub-id-type="pmcid">PMC1693594</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref21">
        <label>21</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Suzuki</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Shimada</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Makizako</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Doi</surname>
              <given-names>Takehiko</given-names>
            </name>
            <name name-style="western">
              <surname>Yoshida</surname>
              <given-names>Daisuke</given-names>
            </name>
            <name name-style="western">
              <surname>Ito</surname>
              <given-names>Kengo</given-names>
            </name>
            <name name-style="western">
              <surname>Shimokata</surname>
              <given-names>Hiroshi</given-names>
            </name>
            <name name-style="western">
              <surname>Washimi</surname>
              <given-names>Yukihiko</given-names>
            </name>
            <name name-style="western">
              <surname>Endo</surname>
              <given-names>Hidetoshi</given-names>
            </name>
            <name name-style="western">
              <surname>Kato</surname>
              <given-names>Takashi</given-names>
            </name>
          </person-group>
          <article-title>A randomized controlled trial of multicomponent exercise in older adults with mild cognitive impairment</article-title>
          <source>PLoS One</source>
          <year>2013</year>
          <volume>8</volume>
          <issue>4</issue>
          <fpage>e61483</fpage>
          <lpage>e63013</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://dx.plos.org/10.1371/journal.pone.0061483"/>
          </comment>
          <pub-id pub-id-type="doi">10.1371/journal.pone.0061483</pub-id>
          <pub-id pub-id-type="medline">23585901</pub-id>
          <pub-id pub-id-type="pii">PONE-D-11-23873</pub-id>
          <pub-id pub-id-type="pmcid">PMC3621765</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref22">
        <label>22</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Page</surname>
              <given-names>MJ</given-names>
            </name>
            <name name-style="western">
              <surname>McKenzie</surname>
              <given-names>JE</given-names>
            </name>
            <name name-style="western">
              <surname>Bossuyt</surname>
              <given-names>PM</given-names>
            </name>
            <name name-style="western">
              <surname>Boutron</surname>
              <given-names>I</given-names>
            </name>
            <name name-style="western">
              <surname>Hoffmann</surname>
              <given-names>TC</given-names>
            </name>
            <name name-style="western">
              <surname>Mulrow</surname>
              <given-names>CD</given-names>
            </name>
            <name name-style="western">
              <surname>Shamseer</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Tetzlaff</surname>
              <given-names>JM</given-names>
            </name>
            <name name-style="western">
              <surname>Akl</surname>
              <given-names>EA</given-names>
            </name>
            <name name-style="western">
              <surname>Brennan</surname>
              <given-names>SE</given-names>
            </name>
            <name name-style="western">
              <surname>Chou</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Glanville</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Grimshaw</surname>
              <given-names>JM</given-names>
            </name>
            <name name-style="western">
              <surname>Hróbjartsson</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Lalu</surname>
              <given-names>MM</given-names>
            </name>
            <name name-style="western">
              <surname>Li</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Loder</surname>
              <given-names>EW</given-names>
            </name>
            <name name-style="western">
              <surname>Mayo-Wilson</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>McDonald</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>McGuinness</surname>
              <given-names>LA</given-names>
            </name>
            <name name-style="western">
              <surname>Stewart</surname>
              <given-names>LA</given-names>
            </name>
            <name name-style="western">
              <surname>Thomas</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Tricco</surname>
              <given-names>AC</given-names>
            </name>
            <name name-style="western">
              <surname>Welch</surname>
              <given-names>VA</given-names>
            </name>
            <name name-style="western">
              <surname>Whiting</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Moher</surname>
              <given-names>D</given-names>
            </name>
          </person-group>
          <article-title>The PRISMA 2020 statement: an updated guideline for reporting systematic reviews</article-title>
          <source>BMJ</source>
          <year>2021</year>
          <volume>372</volume>
          <fpage>n71</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="http://www.bmj.com/lookup/pmidlookup?view=long&amp;pmid=33782057"/>
          </comment>
          <pub-id pub-id-type="doi">10.1136/bmj.n71</pub-id>
          <pub-id pub-id-type="medline">33782057</pub-id>
          <pub-id pub-id-type="pmcid">PMC8005924</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref23">
        <label>23</label>
        <nlm-citation citation-type="web">
          <article-title>Questions to assist with the critical appraisal of cross-sectional studies</article-title>
          <source>Specialist Unit for Review Evidence (SURE)</source>
          <year>2018</year>
          <access-date>2024-07-24</access-date>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.cardiff.ac.uk/__data/assets/pdf_file/0010/1142974/SURE-CA-form-for-Cross-sectional_2018.pdf">https://www.cardiff.ac.uk/__data/assets/pdf_file/0010/1142974/SURE-CA-form-for-Cross-sectional_2018.pdf</ext-link>
          </comment>
        </nlm-citation>
      </ref>
      <ref id="ref24">
        <label>24</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Cimolin</surname>
              <given-names>V</given-names>
            </name>
            <name name-style="western">
              <surname>Vismara</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Ferraris</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Amprimo</surname>
              <given-names>G</given-names>
            </name>
            <name name-style="western">
              <surname>Pettiti</surname>
              <given-names>G</given-names>
            </name>
            <name name-style="western">
              <surname>Lopez</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Galli</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Cremascoli</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Sinagra</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Mauro</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Priano</surname>
              <given-names>L</given-names>
            </name>
          </person-group>
          <article-title>Computation of gait parameters in post stroke and Parkinson's disease: a comparative study using RGB-D sensors and optoelectronic systems</article-title>
          <source>Sensors (Basel)</source>
          <year>2022</year>
          <volume>22</volume>
          <issue>3</issue>
          <fpage>824</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="http://hdl.handle.net/2318/1862921"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/s22030824</pub-id>
          <pub-id pub-id-type="medline">35161570</pub-id>
          <pub-id pub-id-type="pii">s22030824</pub-id>
          <pub-id pub-id-type="pmcid">PMC8839392</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref25">
        <label>25</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Kaur</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Motl</surname>
              <given-names>RW</given-names>
            </name>
            <name name-style="western">
              <surname>Sowers</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Hernandez</surname>
              <given-names>ME</given-names>
            </name>
          </person-group>
          <article-title>A vision-based framework for predicting multiple sclerosis and Parkinson's disease gait dysfunctions—a deep learning approach</article-title>
          <source>IEEE J Biomed Health Inform</source>
          <year>2023</year>
          <volume>27</volume>
          <issue>1</issue>
          <fpage>190</fpage>
          <lpage>201</lpage>
          <pub-id pub-id-type="doi">10.1109/JBHI.2022.3208077</pub-id>
          <pub-id pub-id-type="medline">36126031</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref26">
        <label>26</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Khan</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Zeeshan</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Dougherty</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
          <article-title>A novel method for automatic classification of Parkinson gait severity using front-view video analysis</article-title>
          <source>Technol Health Care</source>
          <year>2021</year>
          <volume>29</volume>
          <issue>4</issue>
          <fpage>643</fpage>
          <lpage>653</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://europepmc.org/abstract/MED/33427697"/>
          </comment>
          <pub-id pub-id-type="doi">10.3233/THC-191960</pub-id>
          <pub-id pub-id-type="medline">33427697</pub-id>
          <pub-id pub-id-type="pii">THC191960</pub-id>
          <pub-id pub-id-type="pmcid">PMC9789477</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref27">
        <label>27</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Khan</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Westin</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Dougherty</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
          <article-title>Motion cue analysis for parkinsonian gait recognition</article-title>
          <source>Open Biomed Eng J</source>
          <year>2013</year>
          <volume>7</volume>
          <fpage>1</fpage>
          <lpage>8</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://europepmc.org/abstract/MED/23407764"/>
          </comment>
          <pub-id pub-id-type="doi">10.2174/1874120701307010001</pub-id>
          <pub-id pub-id-type="medline">23407764</pub-id>
          <pub-id pub-id-type="pii">TOBEJ-7-1</pub-id>
          <pub-id pub-id-type="pmcid">PMC3568887</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref28">
        <label>28</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Lai</surname>
              <given-names>YR</given-names>
            </name>
            <name name-style="western">
              <surname>Lien</surname>
              <given-names>CY</given-names>
            </name>
            <name name-style="western">
              <surname>Huang</surname>
              <given-names>CC</given-names>
            </name>
            <name name-style="western">
              <surname>Lin</surname>
              <given-names>WC</given-names>
            </name>
            <name name-style="western">
              <surname>Chen</surname>
              <given-names>YS</given-names>
            </name>
            <name name-style="western">
              <surname>Yu</surname>
              <given-names>CC</given-names>
            </name>
            <name name-style="western">
              <surname>Cheng</surname>
              <given-names>BC</given-names>
            </name>
            <name name-style="western">
              <surname>Kung</surname>
              <given-names>CT</given-names>
            </name>
            <name name-style="western">
              <surname>Kung</surname>
              <given-names>CF</given-names>
            </name>
            <name name-style="western">
              <surname>Chiang</surname>
              <given-names>YF</given-names>
            </name>
            <name name-style="western">
              <surname>Hung</surname>
              <given-names>YT</given-names>
            </name>
            <name name-style="western">
              <surname>Chang</surname>
              <given-names>HW</given-names>
            </name>
            <name name-style="western">
              <surname>Lu</surname>
              <given-names>CH</given-names>
            </name>
          </person-group>
          <article-title>Clinical disease severity mediates the relationship between stride length and speed and the risk of falling in Parkinson's disease</article-title>
          <source>J Pers Med</source>
          <year>2022</year>
          <volume>12</volume>
          <issue>2</issue>
          <fpage>192</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.mdpi.com/resolver?pii=jpm12020192"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/jpm12020192</pub-id>
          <pub-id pub-id-type="medline">35207680</pub-id>
          <pub-id pub-id-type="pii">jpm12020192</pub-id>
          <pub-id pub-id-type="pmcid">PMC8875632</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref29">
        <label>29</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Li</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Chen</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Hu</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Ma</surname>
              <given-names>Y</given-names>
            </name>
            <name name-style="western">
              <surname>Wu</surname>
              <given-names>Z</given-names>
            </name>
            <name name-style="western">
              <surname>Wan</surname>
              <given-names>W</given-names>
            </name>
            <name name-style="western">
              <surname>Huang</surname>
              <given-names>Y</given-names>
            </name>
            <name name-style="western">
              <surname>Jia</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Gong</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Wan</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Li</surname>
              <given-names>L</given-names>
            </name>
          </person-group>
          <article-title>Automatic Timed Up-and-Go sub-task segmentation for Parkinson's disease patients using video-based activity classification</article-title>
          <source>IEEE Trans Neural Syst Rehabil Eng</source>
          <year>2018</year>
          <volume>26</volume>
          <issue>11</issue>
          <fpage>2189</fpage>
          <lpage>2199</lpage>
          <pub-id pub-id-type="doi">10.1109/TNSRE.2018.2875738</pub-id>
          <pub-id pub-id-type="medline">30334764</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref30">
        <label>30</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Morinan</surname>
              <given-names>G</given-names>
            </name>
            <name name-style="western">
              <surname>Peng</surname>
              <given-names>Y</given-names>
            </name>
            <name name-style="western">
              <surname>Rupprechter</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Weil</surname>
              <given-names>RS</given-names>
            </name>
            <name name-style="western">
              <surname>Leyland</surname>
              <given-names>LA</given-names>
            </name>
            <name name-style="western">
              <surname>Foltynie</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Sibley</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Baig</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Morgante</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Gilron</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Wilt</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Starr</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>O'Keeffe</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
          <article-title>Computer-vision based method for quantifying rising from chair in Parkinson's disease patients</article-title>
          <source>Intell Based Med</source>
          <year>2022</year>
          <volume>6</volume>
          <fpage>100046</fpage>
          <pub-id pub-id-type="doi">10.1016/j.ibmed.2021.100046</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref31">
        <label>31</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Muñoz-Ospina</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Alvarez-Garcia</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Clavijo-Moran</surname>
              <given-names>HJC</given-names>
            </name>
            <name name-style="western">
              <surname>Valderrama-Chaparro</surname>
              <given-names>JA</given-names>
            </name>
            <name name-style="western">
              <surname>García-Peña</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Herrán</surname>
              <given-names>CA</given-names>
            </name>
            <name name-style="western">
              <surname>Urcuqui</surname>
              <given-names>CC</given-names>
            </name>
            <name name-style="western">
              <surname>Navarro-Cadavid</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Orozco</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
          <article-title>Machine learning classifiers to evaluate data from gait analysis with depth cameras in patients with parkinson's disease</article-title>
          <source>Front Hum Neurosci</source>
          <year>2022</year>
          <volume>16</volume>
          <fpage>826376</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://europepmc.org/abstract/MED/35664343"/>
          </comment>
          <pub-id pub-id-type="doi">10.3389/fnhum.2022.826376</pub-id>
          <pub-id pub-id-type="medline">35664343</pub-id>
          <pub-id pub-id-type="pmcid">PMC9160309</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref32">
        <label>32</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Ospina</surname>
              <given-names>BM</given-names>
            </name>
            <name name-style="western">
              <surname>Chaparro</surname>
              <given-names>JAV</given-names>
            </name>
            <name name-style="western">
              <surname>Paredes</surname>
              <given-names>JDA</given-names>
            </name>
            <name name-style="western">
              <surname>Pino</surname>
              <given-names>YJC</given-names>
            </name>
            <name name-style="western">
              <surname>Navarro</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Orozco</surname>
              <given-names>JL</given-names>
            </name>
          </person-group>
          <article-title>Objective arm swing analysis in early-stage Parkinson's disease using an RGB-D camera (Kinect®)</article-title>
          <source>J Parkinsons Dis</source>
          <year>2021</year>
          <volume>11</volume>
          <issue>1</issue>
          <fpage>375</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://europepmc.org/abstract/MED/32144997"/>
          </comment>
          <pub-id pub-id-type="doi">10.3233/JPD-200001</pub-id>
          <pub-id pub-id-type="medline">32144997</pub-id>
          <pub-id pub-id-type="pii">JPD200001</pub-id>
          <pub-id pub-id-type="pmcid">PMC8090988</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref33">
        <label>33</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Otte</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Ellermeyer</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Vater</surname>
              <given-names>TS</given-names>
            </name>
            <name name-style="western">
              <surname>Voigt</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Kroneberg</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Rasche</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Krüger</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Röhling</surname>
              <given-names>HM</given-names>
            </name>
            <name name-style="western">
              <surname>Kayser</surname>
              <given-names>B</given-names>
            </name>
            <name name-style="western">
              <surname>Mansow-Model</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Klostermann</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Brandt</surname>
              <given-names>AU</given-names>
            </name>
            <name name-style="western">
              <surname>Paul</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Lipp</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Schmitz-Hübsch</surname>
              <given-names>T</given-names>
            </name>
          </person-group>
          <article-title>Instrumental assessment of stepping in place captures clinically relevant motor symptoms of Parkinson's disease</article-title>
          <source>Sensors (Basel)</source>
          <year>2020</year>
          <volume>20</volume>
          <issue>19</issue>
          <fpage>5465</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.mdpi.com/resolver?pii=s20195465"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/s20195465</pub-id>
          <pub-id pub-id-type="medline">32977647</pub-id>
          <pub-id pub-id-type="pii">s20195465</pub-id>
          <pub-id pub-id-type="pmcid">PMC7582555</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref34">
        <label>34</label>
        <nlm-citation citation-type="confproc">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Pedro</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Kirsten</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Sebastian</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Kathrin</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Karsten</surname>
              <given-names>W</given-names>
            </name>
            <name name-style="western">
              <surname>Andreas</surname>
              <given-names>H</given-names>
            </name>
          </person-group>
          <article-title>Preliminary viability test of a 3-D-consumer-camera-based system for automatic gait feature detection in people with and without Parkinson's disease</article-title>
          <year>2020</year>
          <conf-name>2020 IEEE International Conference on Healthcare Informatics (ICHI)</conf-name>
          <conf-date>2020 Nov 30</conf-date>
          <conf-loc>Germany</conf-loc>
          <pub-id pub-id-type="doi">10.1109/ichi48887.2020.9374363</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref35">
        <label>35</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Procházka</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Vyšata</surname>
              <given-names>O</given-names>
            </name>
            <name name-style="western">
              <surname>Vališ</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Ťupa</surname>
              <given-names>O</given-names>
            </name>
            <name name-style="western">
              <surname>Schätz</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Mařík</surname>
              <given-names>V</given-names>
            </name>
          </person-group>
          <article-title>Use of the image and depth sensors of the Microsoft Kinect for the detection of gait disorders</article-title>
          <source>Neural Comput Appl</source>
          <year>2015</year>
          <volume>26</volume>
          <issue>7</issue>
          <fpage>1621</fpage>
          <lpage>1629</lpage>
          <pub-id pub-id-type="doi">10.1007/s00521-015-1827-x</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref36">
        <label>36</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Rupprechter</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Morinan</surname>
              <given-names>G</given-names>
            </name>
            <name name-style="western">
              <surname>Peng</surname>
              <given-names>Y</given-names>
            </name>
            <name name-style="western">
              <surname>Foltynie</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>Sibley</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Weil</surname>
              <given-names>RS</given-names>
            </name>
            <name name-style="western">
              <surname>Leyland</surname>
              <given-names>LA</given-names>
            </name>
            <name name-style="western">
              <surname>Baig</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Morgante</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Gilron</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Wilt</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Starr</surname>
              <given-names>P</given-names>
            </name>
            <name name-style="western">
              <surname>Hauser</surname>
              <given-names>RA</given-names>
            </name>
            <name name-style="western">
              <surname>O'Keeffe</surname>
              <given-names>J</given-names>
            </name>
          </person-group>
          <article-title>A clinically interpretable computer-vision based method for quantifying gait in Parkinson's disease</article-title>
          <source>Sensors (Basel)</source>
          <year>2021</year>
          <volume>21</volume>
          <issue>16</issue>
          <fpage>5437</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.mdpi.com/resolver?pii=s21165437"/>
          </comment>
          <pub-id pub-id-type="doi">10.3390/s21165437</pub-id>
          <pub-id pub-id-type="medline">34450879</pub-id>
          <pub-id pub-id-type="pii">s21165437</pub-id>
          <pub-id pub-id-type="pmcid">PMC8399017</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref37">
        <label>37</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Sabo</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Gorodetsky</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Fasano</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Iaboni</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Taati</surname>
              <given-names>B</given-names>
            </name>
          </person-group>
          <article-title>Concurrent validity of Zeno instrumented walkway and video-based gait features in adults with Parkinson's disease</article-title>
          <source>IEEE J Transl Eng Health Med</source>
          <year>2022</year>
          <volume>10</volume>
          <fpage>2100511</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://europepmc.org/abstract/MED/35795874"/>
          </comment>
          <pub-id pub-id-type="doi">10.1109/JTEHM.2022.3180231</pub-id>
          <pub-id pub-id-type="medline">35795874</pub-id>
          <pub-id pub-id-type="pii">2100511</pub-id>
          <pub-id pub-id-type="pmcid">PMC9252334</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref38">
        <label>38</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Sabo</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Mehdizadeh</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Ng</surname>
              <given-names>KD</given-names>
            </name>
            <name name-style="western">
              <surname>Iaboni</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Taati</surname>
              <given-names>B</given-names>
            </name>
          </person-group>
          <article-title>Assessment of Parkinsonian gait in older adults with dementia via human pose tracking in video data</article-title>
          <source>J Neuroeng Rehabil</source>
          <year>2020</year>
          <volume>17</volume>
          <issue>1</issue>
          <fpage>97</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://jneuroengrehab.biomedcentral.com/articles/10.1186/s12984-020-00728-9"/>
          </comment>
          <pub-id pub-id-type="doi">10.1186/s12984-020-00728-9</pub-id>
          <pub-id pub-id-type="medline">32664973</pub-id>
          <pub-id pub-id-type="pii">10.1186/s12984-020-00728-9</pub-id>
          <pub-id pub-id-type="pmcid">PMC7362631</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref39">
        <label>39</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Seifallahi</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Hassani Mehraban</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Khamseh</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Salehi</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Hajati</surname>
              <given-names>G</given-names>
            </name>
            <name name-style="western">
              <surname>Khansari</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Ahmadzadeh</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Babaie</surname>
              <given-names>M</given-names>
            </name>
          </person-group>
          <article-title>Detection of mild cognitive impairment from gait using adaptive neuro-fuzzy inference system</article-title>
          <source>Biomed Signal Process Control</source>
          <year>2022</year>
          <volume>71</volume>
          <fpage>103195</fpage>
          <pub-id pub-id-type="doi">10.1016/j.bspc.2021.103195</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref40">
        <label>40</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Shin</surname>
              <given-names>JH</given-names>
            </name>
            <name name-style="western">
              <surname>Yu</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Ong</surname>
              <given-names>JN</given-names>
            </name>
            <name name-style="western">
              <surname>Lee</surname>
              <given-names>CY</given-names>
            </name>
            <name name-style="western">
              <surname>Jeon</surname>
              <given-names>SH</given-names>
            </name>
            <name name-style="western">
              <surname>Park</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Kim</surname>
              <given-names>HJ</given-names>
            </name>
            <name name-style="western">
              <surname>Lee</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Jeon</surname>
              <given-names>B</given-names>
            </name>
          </person-group>
          <article-title>Quantitative gait analysis using a pose-estimation algorithm with a single 2D-video of Parkinson's disease patients</article-title>
          <source>J Parkinsons Dis</source>
          <year>2021</year>
          <volume>11</volume>
          <issue>3</issue>
          <fpage>1271</fpage>
          <lpage>1283</lpage>
          <pub-id pub-id-type="doi">10.3233/JPD-212544</pub-id>
          <pub-id pub-id-type="medline">33935106</pub-id>
          <pub-id pub-id-type="pii">JPD212544</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref41">
        <label>41</label>
        <nlm-citation citation-type="confproc">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Soltaninejad</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Rosales-Castellanos</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Ba</surname>
              <given-names>F</given-names>
            </name>
            <name name-style="western">
              <surname>Ibarra-Manzano</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Cheng</surname>
              <given-names>I</given-names>
            </name>
          </person-group>
          <article-title>Body movement monitoring for Parkinson's disease patients using a smart sensor based non-invasive technique</article-title>
          <year>2018</year>
          <conf-name>2018 IEEE 20th International Conference on e-Health Networking, Applications and Services (Healthcom)</conf-name>
          <conf-date>2018 Sep 17</conf-date>
          <conf-loc>Czech Republic</conf-loc>
          <fpage>1</fpage>
          <lpage>6</lpage>
          <pub-id pub-id-type="doi">10.1109/healthcom.2018.8531197</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref42">
        <label>42</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Tan</surname>
              <given-names>D</given-names>
            </name>
            <name name-style="western">
              <surname>Pua</surname>
              <given-names>YH</given-names>
            </name>
            <name name-style="western">
              <surname>Balakrishnan</surname>
              <given-names>S</given-names>
            </name>
            <name name-style="western">
              <surname>Scully</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Bower</surname>
              <given-names>KJ</given-names>
            </name>
            <name name-style="western">
              <surname>Prakash</surname>
              <given-names>KM</given-names>
            </name>
            <name name-style="western">
              <surname>Tan</surname>
              <given-names>EK</given-names>
            </name>
            <name name-style="western">
              <surname>Chew</surname>
              <given-names>JS</given-names>
            </name>
            <name name-style="western">
              <surname>Poh</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>Tan</surname>
              <given-names>SB</given-names>
            </name>
            <name name-style="western">
              <surname>Clark</surname>
              <given-names>RA</given-names>
            </name>
          </person-group>
          <article-title>Automated analysis of gait and modified Timed Up and Go using the Microsoft Kinect in people with Parkinson's disease: associations with physical outcome measures</article-title>
          <source>Med Biol Eng Comput</source>
          <year>2019</year>
          <volume>57</volume>
          <issue>2</issue>
          <fpage>369</fpage>
          <lpage>377</lpage>
          <pub-id pub-id-type="doi">10.1007/s11517-018-1868-2</pub-id>
          <pub-id pub-id-type="medline">30123947</pub-id>
          <pub-id pub-id-type="pii">10.1007/s11517-018-1868-2</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref43">
        <label>43</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Ťupa</surname>
              <given-names>O</given-names>
            </name>
            <name name-style="western">
              <surname>Procházka</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Vyšata</surname>
              <given-names>O</given-names>
            </name>
            <name name-style="western">
              <surname>Schätz</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Mareš</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Vališ</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Mařík</surname>
              <given-names>V</given-names>
            </name>
          </person-group>
          <article-title>Motion tracking and gait feature estimation for recognising Parkinson's disease using MS kinect</article-title>
          <source>Biomed Eng Online</source>
          <year>2015</year>
          <volume>14</volume>
          <fpage>97</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://biomedical-engineering-online.biomedcentral.com/articles/10.1186/s12938-015-0092-7"/>
          </comment>
          <pub-id pub-id-type="doi">10.1186/s12938-015-0092-7</pub-id>
          <pub-id pub-id-type="medline">26499251</pub-id>
          <pub-id pub-id-type="pii">10.1186/s12938-015-0092-7</pub-id>
          <pub-id pub-id-type="pmcid">PMC4619468</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref44">
        <label>44</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Bridenbaugh</surname>
              <given-names>SA</given-names>
            </name>
            <name name-style="western">
              <surname>Kressig</surname>
              <given-names>RW</given-names>
            </name>
          </person-group>
          <article-title>Motor cognitive dual tasking: early detection of gait impairment, fall risk and cognitive decline</article-title>
          <source>Z Gerontol Geriatr</source>
          <year>2015</year>
          <volume>48</volume>
          <issue>1</issue>
          <fpage>15</fpage>
          <lpage>21</lpage>
          <pub-id pub-id-type="doi">10.1007/s00391-014-0845-0</pub-id>
          <pub-id pub-id-type="medline">25633391</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref45">
        <label>45</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Montero-Odasso</surname>
              <given-names>MM</given-names>
            </name>
            <name name-style="western">
              <surname>Sarquis-Adamson</surname>
              <given-names>Y</given-names>
            </name>
            <name name-style="western">
              <surname>Speechley</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Borrie</surname>
              <given-names>MJ</given-names>
            </name>
            <name name-style="western">
              <surname>Hachinski</surname>
              <given-names>VC</given-names>
            </name>
            <name name-style="western">
              <surname>Wells</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Riccio</surname>
              <given-names>PM</given-names>
            </name>
            <name name-style="western">
              <surname>Schapira</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Sejdic</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>Camicioli</surname>
              <given-names>RM</given-names>
            </name>
            <name name-style="western">
              <surname>Bartha</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>McIlroy</surname>
              <given-names>WE</given-names>
            </name>
            <name name-style="western">
              <surname>Muir-Hunter</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
          <article-title>Association of dual-task gait with incident dementia in mild cognitive impairment: results from the gait and brain study</article-title>
          <source>JAMA Neurol</source>
          <year>2017</year>
          <volume>74</volume>
          <issue>7</issue>
          <fpage>857</fpage>
          <lpage>865</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://europepmc.org/abstract/MED/28505243"/>
          </comment>
          <pub-id pub-id-type="doi">10.1001/jamaneurol.2017.0643</pub-id>
          <pub-id pub-id-type="medline">28505243</pub-id>
          <pub-id pub-id-type="pii">2625135</pub-id>
          <pub-id pub-id-type="pmcid">PMC5710533</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref46">
        <label>46</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Åhman</surname>
              <given-names>HB</given-names>
            </name>
            <name name-style="western">
              <surname>Cedervall</surname>
              <given-names>Y</given-names>
            </name>
            <name name-style="western">
              <surname>Kilander</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Giedraitis</surname>
              <given-names>V</given-names>
            </name>
            <name name-style="western">
              <surname>Berglund</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>McKee</surname>
              <given-names>KJ</given-names>
            </name>
            <name name-style="western">
              <surname>Rosendahl</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>Ingelsson</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Åberg</surname>
              <given-names>AC</given-names>
            </name>
          </person-group>
          <article-title>Dual-task tests discriminate between dementia, mild cognitive impairment, subjective cognitive impairment, and healthy controls—a cross-sectional cohort study</article-title>
          <source>BMC Geriatr</source>
          <year>2020</year>
          <volume>20</volume>
          <issue>1</issue>
          <fpage>258</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://bmcgeriatr.biomedcentral.com/articles/10.1186/s12877-020-01645-1"/>
          </comment>
          <pub-id pub-id-type="doi">10.1186/s12877-020-01645-1</pub-id>
          <pub-id pub-id-type="medline">32727472</pub-id>
          <pub-id pub-id-type="pii">10.1186/s12877-020-01645-1</pub-id>
          <pub-id pub-id-type="pmcid">PMC7392684</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref47">
        <label>47</label>
        <nlm-citation citation-type="confproc">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Ye</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Yang</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Stankovic</surname>
              <given-names>V</given-names>
            </name>
            <name name-style="western">
              <surname>Stankovic</surname>
              <given-names>L</given-names>
            </name>
            <name name-style="western">
              <surname>Cheng</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
          <article-title>Gait phase classification for in-home gait assessment</article-title>
          <year>2017</year>
          <conf-name>2017 IEEE International Conference on Multimedia and Expo (ICME)</conf-name>
          <conf-date>2017 July 10</conf-date>
          <conf-loc>Hong Kong, China</conf-loc>
          <fpage>1524</fpage>
          <lpage>1529</lpage>
          <pub-id pub-id-type="doi">10.1109/icme.2017.8019500</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref48">
        <label>48</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Park</surname>
              <given-names>SH</given-names>
            </name>
            <name name-style="western">
              <surname>Choi</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Byeon</surname>
              <given-names>JS</given-names>
            </name>
          </person-group>
          <article-title>Key principles of clinical validation, device approval, and insurance coverage decisions of artificial intelligence</article-title>
          <source>Korean J Radiol</source>
          <year>2021</year>
          <volume>22</volume>
          <issue>3</issue>
          <fpage>442</fpage>
          <lpage>453</lpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.kjronline.org/DOIx.php?id=10.3348/kjr.2021.0048"/>
          </comment>
          <pub-id pub-id-type="doi">10.3348/kjr.2021.0048</pub-id>
          <pub-id pub-id-type="medline">33629545</pub-id>
          <pub-id pub-id-type="pii">22.442</pub-id>
          <pub-id pub-id-type="pmcid">PMC7909857</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref49">
        <label>49</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Tsay</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Steadman</surname>
              <given-names>N</given-names>
            </name>
            <name name-style="western">
              <surname>Fleming</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Gann</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Di Giulio</surname>
              <given-names>I</given-names>
            </name>
            <name name-style="western">
              <surname>Graef</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Han</surname>
              <given-names>J</given-names>
            </name>
            <name name-style="western">
              <surname>Jayasinghe</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Mitchell</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Chen</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Raheel</surname>
              <given-names>K</given-names>
            </name>
            <name name-style="western">
              <surname>Semedo</surname>
              <given-names>E</given-names>
            </name>
            <name name-style="western">
              <surname>Sîmpetru</surname>
              <given-names>R</given-names>
            </name>
            <name name-style="western">
              <surname>Utami</surname>
              <given-names>KP</given-names>
            </name>
            <name name-style="western">
              <surname>Williams</surname>
              <given-names>A</given-names>
            </name>
            <name name-style="western">
              <surname>Zhu</surname>
              <given-names>Z</given-names>
            </name>
            <name name-style="western">
              <surname>Stagg</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Haar</surname>
              <given-names>S</given-names>
            </name>
          </person-group>
          <article-title>Bridging the gap between experimental control and ecological validity in human sensorimotor science</article-title>
          <source>J Physiol</source>
          <year>2024</year>
          <pub-id pub-id-type="doi">10.1113/JP287037</pub-id>
          <pub-id pub-id-type="medline">38970623</pub-id>
        </nlm-citation>
      </ref>
    </ref-list>
  </back>
</article>
